SERVICING

Design Features Performance

LEVELING AND INSTALLATION REQUIREMENTS

It is extremely important that the unit is level. If it is not level, the ice mold will not fill evenly. This can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt prematurely. See Figure A.

Remember the floor surrounding a drain has a tendency to slope towards the drain.

Leveling the Unit

Figure A

UL307

1.Use a level to check the icemaker from front to back and from side to side. See Figure B. Use a level to check the levelness of the icemaker from front to back and from side to side by placing a level on the inside edge and along the door seal edge for built-in installation. See Figure B.

FRONT

SIDE

CLRCO029

 

CLRCO006

 

 

Figure B

2.If the icemaker is not level, adjust the feet on the corners of the unit as necessary. See Figure C.

3. Check after each adjustment and repeat the previous steps as necessary until the unit is level.

RAISE

LOWER

DWR005

 

 

Installation Requirements

Figure C

The unit may be built into a cabinet. There is no minimum clearance requirement for the top, left or right sides of the unit.

The location must allow enough clearance for water, drain, and electrical connections in the rear of the unit.

The location must not obstruct air flow to the front of the unit.