CONNECTING A DRAIN PUMP
If a gravity drain connection is not available, and you have not purchased the CLRCO2075 with factory installed pump, we strongly recommend the use of the
•It must be UL listed and have a UL listed, 120 VAC,
•It must have overall maximum outside dimensions of
•It must have a minimum flow rate of 15 gallons per hour at 10 feet of lift.
•It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure.
•It must have a check valve in the discharge line to prevent waste water return to the pump.
•It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.
•It must have an operating temperature range of 50°F to 110°F (10°C to 40°C).
CAUTION
In the event of a power outage, restricted drain or pump failure, the failure to use the