Automatic Voltage Regulation (AVR)
Protect your computer from electrical damage caused by dangerous "spikes and sags".$125,000 Limited Warranty
Includes
UPS Monitoring
Software

Uninterrupted

Power Supply (UPS)

The Ultimate Power Protection!If you're looking for the most complete, technologically advanced power protection unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an absolute must for anyone running a small server, workstation or a powerful PC. You simply cannot afford to cut corners when it comes to safeguarding your valuable equipment, and these UPS's deliver the comprehensive protection for computer, peripherals and data files at a remarkably low price. Features
- Line Interactive Design
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
Gneral Sku
Backup Time
Net Weight Kg (lbs)
Digital Display
Output Watts
UPS Capacity
No. of Sockets
Voltage (Battery)
Frequency (Battery)
Transfer Time
Input Voltage (Single Phase)
Frequency
Protection Unit Input
Overload Protection
Short Circuit
Surge Protection
Battery Type
Typical Recharge Time
Protection
Interface USB
Alarm Battery Backup
Battery Low
Abnormal Charge
Overload
Environment Ambient Operation
1500VA 2000VA
ULT33045 ULT33046
About 60 Minutes About 65 Minutes
Yes Yes
900 1200
1500VA 2000VA
St
y
le A UPSx4
,
B
yp
assx2 St
y
le A UPSx4
,
B
yp
assx2
Simulated square wave output at nominal +/-5% Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz 50 or 60Hz +/- 0.3Hz
2-4 milliseconds
,
includin
g
detection time 2-4 milliseconds
,
includin
g
detection time
120V +15%/-20% at line in
p
ut 120V +15%/-20% at line in
p
ut
50 or 60Hz +/- 10%
(
auto sensin
g)
50 or 60Hz +/- 10%
(
auto sensin
g)
Circuit breaker for overload & short circuit
p
rotection Circuit breaker for overload & short circuit
p
rotection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS out
p
ut shuts off immediatel
y
UPS out
p
ut shuts off immediatel
y
2100 Joules 2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
6 hours (to 90% of full capacity) 6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Slow bee
p
in
g
sound ever
y
4 seconds Slow bee
p
in
g
sound ever
y
4 seconds
Ra
p
id bee
p
in
g
sound ever
y
second Ra
p
id bee
p
in
g
sound ever
y
second
AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second
Continue beeping sound Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation
),
Tem
p
erature: 0-30͠
3,500m max, Humidity: 0%-95%(without
condensation formation
),
Tem
p
erature: 0-30͠
1000VA 1025VA
ULT31502 ULT33044
About 50 Minutes About 50 Minutes
28.6(63.0) 28.6(63.0)
Yes Yes
615 615
1025VA 1025VA
St
y
le A UPSx4
,
B
yp
assx2 St
y
le A UPSx4
,
B
yp
assx2
Simulated square wave output at nominal +/-5% Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz 50 or 60Hz +/- 0.3Hz
2-4 milliseconds
,
includin
g
detection time 2-4 milliseconds
,
includin
g
detection time
120V +15%/-20% at line in
p
ut 120V +15%/-20% at line in
p
ut
50 or 60Hz +/- 10%
(
auto sensin
g)
50 or 60Hz +/- 10%
(
auto sensin
g)
Circuit breaker for overload & short circuit
p
rotection Circuit breaker for overload & short circuit
p
rotection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
UPS out
p
ut shuts off immediatel
y
UPS out
p
ut shuts off immediatel
y
2100 Joules 2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
6 hours (to 90% of full capacity) 6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Slow bee
p
in
g
sound ever
y
4 seconds Slow bee
p
in
g
sound ever
y
4 seconds
Ra
p
id bee
p
in
g
sound ever
y
second Ra
p
id bee
p
in
g
sound ever
y
second
AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second
Continue beeping sound Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation
),
Tem
p
erature: 0-30͠
3,500m max, Humidity: 0%-95%(without
condensation formation
),
Tem
p
erature: 0-30͠
IncludesUPS MonitoringSoftware