14
TECHNICAL SPECIFICATIONS
Table 4 - Technical Specifications

Model: MP13A MP16A MP22A MP36C MP49C

Flow Rate (GPM): 2 3 6 12 20
Inlet\Outlet Size: 1/2"m NPT 3/4"m NPT 3/4"m NPT 1"m NPT 1-1/2"m NPT
Number of Lamps: 1 1 1 1 1
Lamp Model No.: GPH212T5L GPH287T5L GPH436T5L G36T6L G48T6L
Length: 13-1/2"16-1/2"22-1/2"36-1/2"49-1/2"
Width: 4-5/16"4-5/16"4-5/16"5-11/16"5- 11/16"
Height: 8-3/8"8- 3/8"8-3/8"9-1/2"9-1/2"
Chamber Diameter: 4-1/4"4-1/4"4- 1/4"4-1/4"4-1/4"
Shipping Weight: 12 Lbs 12 Lbs 14 Lbs 22 Lbs 36 Lbs
Voltage:c120V 120V 120V 120V 120V
Amps: .17A .23A .33A .65A .42A
Frequency: 60Hz 60Hz 60Hz 60Hz 60Hz
Power Consumption:d14 Watts 18 Watts 24 Watts 44 Watts 54 Watts
Lamp Watts: 10 Watts 14 Watts 20 Watts 39 Watts 50 Watts
Max Operating Pressure: 100 PSI 100 PSI 100 PSI 100 PSI 100 PSI
Ambient Temperature: 33° F - 100° F 33° F - 100° F 33° F - 100° F 33° F - 100° F 33° F - 100° F
Quartz Sleeve: 1 1 1 1 1
Drain Plug: 1/4"NPT 1/4"NPT 1/4"NPT 1/4"NPT 1/4"NPT
Lamp Out Translucent Translucent Translucent Translucent Translucent
Indicator: Sight Port Sight Port Sight Port Sight Port Sight Port
Ultraviolet Monitor: Optional Optional Optional Optional Optional
Audio Alarm: Optional Optional Optional Optional Optional
Solenoid Valve: Optional Optional Optional Optional Optional
Time Delay Mechanism: Optional Optional Optional Optional Optional
Elapsed Time Indicator: Optional Optional Optional Optional Optional
Quantum Optional Optional Optional Optional Optional
Thermal Optimizer:
c220V 50Hz, 220V 60Hz, 12V, or 24VDC units are also available. Consult Factory for specific voltage requirements.
dTotal power consumption, including ballast loss.