5
INSTALLATION
LOCATION
1. The water purifier is intended for indoor use only. The water purifier should be protected from the elements and
from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be
between 33F and 100F.
2. Electrical power supplied to the water purifier MUST match power requirements listed on the water purifier. Use
of a voltage surge protector is recommended.
3. Plug water purifier into an approved ground fault circuit interrupt (GFCI) receptacle.
4. The water purifier should be located in a dry, well-lit area, which provides enough room to perform routine
maintenance. This includes a minimum distance of one chamber length from the chamber end, to allow for
cleaning and/or the changing of the lamp and quartz sleeve as well as a minimum of 6" on the opposite end of the
water purifier.
5. The water purifier should always be located closest to the point of use. This reduces the chance of the purified
water being re-contaminated by bacteria in the water distribution system after the water purifier.
6. CAUTION: As with any water handling device, the water purifier should be located in an area where any possible
condensation or leakage from the water purifier, any purifier accessory and/or plumbing will not result in damage
to the area surrounding the water purifier. For added protection, it is recommended that a suitable drain pan be
installed under the purifier. The drain pan must be plumbed to an adequate, free flowing, drain to prevent water
damage in the event of a leak. There are numerous leak detection/flood stop devices, available on the market today,
designed to stop the flow of water, reducing the chance of water damage due to leakage. For more details regard-
ing leak prevention and/or limiting damages due to leaks, please contact the factory.
7. The water purifier should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon
Filters, Pre-Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purified water
being re-contaminated by bacteria in any of these units.
DIMENSIONAL DATA
Figure 1 - MightyPureDimensional Drawing
Table 2 - MightyPureDimensional Data
Model: A B C D E F G H Inlet/Outlet
MP13A 6" 13" 5-3/4" 7" 13-1/2"3-
5/8"4-
15/16"8-
3/8"1/2"m NPT
MP16A 8-3/4" 16" 8-3/4" 10" 16-1/2"3-
5/8"4-
15/16"8-
3/8"3/4"m NPT
MP22A 14-3/4" 22" 13-1/4" 14-1/2" 22- 1/2"3-
5/8"4-
15/16"8-
3/8"3/4"m NPT
MP36C 28-1/2" 36" 16" 18" 36-1/2"4-
15/16"5-
11/16"9-
1/2" 1"m NPT
MP49C 40-7/8" 49" 26" 30" 49-1/2"4-
15/16"5-
11/16"9-
1/2"1-
1/2"m NPT