OPERATING PROCEDURE TO TRANSMIT
CAUTION
The transmitter Voltage Standing Wave Ratio (V.S.W.R.) measurement must be performed prior to the use of the transmitter. A V.S.W.R. ratio in excess of 2:1 may damage the transmitter.
1.Be sure the operator has read and understands DOTAC Rules and Regulations prior to operating the transmitter.
2.Select the desired channel.
3.If the channel is clear, depress the
OPERATOR TROUBLESHOOTING
Should the unit malfunction or not perform properly, the operator should perform the procedures indicated below:
1.If the transceiver is completely inoperative.
*Check the power cord and fuse.
2.If trouble is experienced with receiving.
*Check ON/OFFVOLUMECONTROLsetting.
*Besure SQUELCH is adjusted properly. Isthe radio over-squelched?
*Check to see that the radio is switched to an operational mode.
3.If trouble is experienced with transmitting.
*Check to see that the transmission line (coaxial cable) is securely connected to the ANTENNA CONNECTOR.
*Be sure that the antenna is fully extended for proper operation.
*Be sure that all transmission line (coaxial cable) connections are secure and free of corrosion.