this setting. The squelch is now properly set. The receiverwill remain quiet until a signal is actually received. Do not advance the control too far, or some weaker signalswill not be heard.

OPERATING PROCEDURE TO TRANSMIT

1.Select the desired channel for transmission.

2.If the channel is clear, depress the push-to-talk switch on the side of the micro- phone and speak in a normal voice.

CAUTION: The transceiver Voltage Standing Wave Ratio (V.S.W.A.) measurement must be performed prior to the use of the transmitter. A "V.S.W.R." ratio in excess of 2:1 may damage the transmitter.

OPERATION OF SSB

Choose the desired side band frequency by, A; select standard channel (1 - 40), B; select Upper or Lower side b~md by moving AM/SSB switch. Transmit or receive according to previous instructions.

When receiving a side band transmission you may need to use the Clarifier control to fine tune that frequency. Rotate the Clarifier clockwise or counterclockwise for optimum reception.

PREVENTATIVE MAINTENANCE

At six to twelve month intervals, the following system checks should be made:

1.Check the Standing Wave Ratio (V.S.W.R.)

2.Inspect all electrical connections.

3.Inspect antenna coaxial cable for wear.

4.Inspect all screws and other mounting hardware.

TROUBLE SHOOTING

If your PC 122 is not performing up to your expectations, please try these simple steps. If you still cannot get satisfactory results after reading this manual and following the trouble shooting steps, you may need to have your unit serviced.

trouble

Unit will not turn on. No power

Poor reception

Weak transmission

check

1.Check power cord and all connections.

2.Check power cord fuse.

3.Check vehicleelectrical system.

1.Check and adjust Squelch.

2.Check antenna system and cable, connectors.

3.Check operation mode of the radio.

1.Check antenna system and cable, connectors.

2.Check antenna grounding.

3. Check for corrosion on connectors.