LP Gas Outdoor Fireplace Model No. GAD1399SP Series

Troubleshooting

Problem

Possible Cause

Prevention/Cure

 

LP gas tank valve is closed

Make sure regulator is securely attached to the LP gas tank, turn LP gas tank

 

valve to “OPEN”

 

 

 

 

 

 

LP gas tank is low or empty

Replace or refill LP gas tank

 

 

 

 

 

1. Turn LP gas tank valve to “CLOSED”

 

LP gas leak

2. Wait 5 minutes for gas to clear

 

 

3. Follow “Checking for Leaks” in the owner’s manual

Burner will not light using ignitor

 

 

Battery needs to be changed

Replace the “AA” battery (follow assembly step for inserting battery)

 

Electrode and burners are wet

Wipe dry with cloth

 

Electrode cracked or broken - sparks at crack

Replace electrode

 

 

 

 

Wire loose or disconnected

Reconnect wire or replace electrode/wire assembly

 

 

 

 

Wire is shorting (sparking) between ignitor and electrode

Replace ignitor wire/electrode assembly

 

 

 

 

Bad ignitor

Replace ignitor

 

 

 

 

 

Check if LP gas tank is empty

 

No gas flow

A. If empty, replace or refill

 

B. If LP gas tank is not empty, refer to “Sudden drop in gas flow or reduced

 

 

 

 

flame height”

 

LP gas tank is low or empty

Replace or refill LP gas tank

 

 

1. Turn LP gas tank valve to “CLOSED”

 

LP gas leak

2. Wait 5 minutes for gas to clear

Burner will not light with match

 

3. Follow “Checking for Leaks” in the owner’s manual

Coupling nut and regulator not fully connected

Turning the coupling nut about one-half to three quarters additional turn until

 

 

solid stop. Tighten by hand only-do not use tools.

 

 

 

Obstruction of gas flow

1. Clear burner tubes

 

2. Check for bent or kinked hose

 

 

 

Disengagement of burner to valve

Reengage burner and valve

 

Spider webs or insect nest in venturi

Clean venturi and burner tube

 

Burner ports clogged or blocked

Clean burner ports

 

Out of gas

Replace or refill LP gas tank

 

 

 

 

 

1. Turn control knob to “OFF ”

 

 

2. Wait 30 seconds and light outdoor fireplace.

 

 

3. If flames are still too low, reset the excessive flow safety device:

 

 

a. Turn control knob(s) “OFF ”

Sudden drop in gas flow or reduced flame height

 

b. Turn LP gas tank valve to “CLOSED”

Excess flow; safety device may have been activated

c. Disconnect regulator

 

d. Turn control knob to (HIGH)

 

 

 

 

e. Wait 1 minute

 

 

f. Turn control knob to “OFF ”

 

 

g. Reconnect regulator and leak check connections.

 

 

h. Slowly turn LP gas tank valve to “OPEN”

 

 

i. Wait 30 seconds and then light outdoor fireplace per “Lighting Instructions”

Irregular flame pattern, flame does not run the

Burner ports are clogged or blocked

Clean burner ports

full length of burner

 

 

 

New burner may have residual manufacturing oils.

Burn outdoor fireplace for 15 minutes and reinspect

Flame is yellow or orange

 

 

Spider webs or insect nest in venturi

Clean venturi

 

 

 

 

Poor alignment of valve to burner venturi

Assure burner venturi is properly engaged with valve

 

 

 

 

High or gusting winds

Do not use outdoor fireplace in high winds

Flame blow out

 

 

Low on LP gas

Replace or refill LP gas tank

 

Excess flow valve tripped

Refer to “Sudden drop in gas flow or reduced flame height”

Flashback (fire in burner tube(s))

Burner and/or burner tubes are blocked

Clean burner and/or burner tubes

 

 

1. Turn LP gas tank valve to “CLOSED”

Flame seems to lose heat when burning in cold

Ice has built up on the outside of the LP gas tank

2. Turn control knob to “OFF ”

3. Replace with a spare LP gas tank

weather - temperature below 50ºF

because the vaporization process is too slow.

4. Reconnect LP gas tank per “Installing LP Gas Tank”

 

 

5. Leak check the connections

 

 

6. Light per “Lighting Instructions”

 

 

 

For more assistance please visit us online at www.bluerhino.com or call 1.800.762.1142.