Operation of the Heater

1.

BE SURE TO PUT A LAYER OF SAND OR FIREBRICK

 

APPROXIMATELY 1 1/2" THICK IN THE BOTTOM OF THE

 

STOVE BEFORE STARTING FIRE.

2.

Burn wood or wood products only. The wood should be air dried

FLUE CONNECTION-NON-COMBUSTIBLE WALL

NONCOMBUSTIBLEWALL

 

for at least six months prior to use for maximum efficiency.

3.

After the fire has been started and is burning satisfactorily,

 

adjust the rate of burning by opening or closing the draft

 

damper wheel on the feed door.

4.

Never build extremely large fires in this type of heater as

 

damage to the heater or smoking may result.

5.

Provide air into the room for combustion.

ELBOW

BAROMETRIC

THIMBLE COLLAR PIPE

6.

Do Not touch the heater after firing until it has cooled.

7.

Do Not use a grate or elevate fire, build fire directly on hearth.

8.

The fuel feed door must remain closed during operation.

Chimney Connection

MASONRY CHIMNEY

The masonry chimney must comply with UL codes. Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the heater. See Page 3, Item 5. Look at Fig. 5. The connector pipe and fittings you will need to connect directly to a masonry chimney are shown. If the connector pipe must go through a combustible wall before entering the masonry chimney, consult a qualified mason or chimney dealer. The installation must conform to local fire codes, and NFPA 211. Do not connect this heater into the same chimney flue as the fireplace or flue from another heater. The chimney used for a heater must not be used to ventilate the cellar or basement. If there is a cleanout opening at the base of the chimney, close it tightly.

UL/ULC LISTED CHIMNEY

Carefully follow chimney manufacturer's instructions. Use only listed type HT per UL 103, 6-in diameter black or blued chimney connector, minimum 24 gauge steel. If your chimney starts at the ceiling (Fig. 6), you will need enough 6" pipe to reach the ceiling. The top of the chimney must be at least 3 feet above the roof and be at least 2 feet higher than any point of the roof within 10 feet. (Fig 6)

RULES FOR CONNECTOR PIPE INSTALLATION

1.Crimped end of the pipe must be installed toward the heater. The pipe should slide into the flue collar. The pipe should be firmly attached to the flue collar with 3 screws and sealed with furnace cement.

2.Slope any horizontal pipe upward toward the chimney at least 1/4 " inch for each foot of horizontal run.

3.You must have at least 18" inches clearance between any horizontal piping and the ceiling. (Fig. 2)

4.The pipe cannot extend into the chimney flue.(Fig. 7)

5.Seal each connector pipe joint with furnace cement. Also seal the pipe at the chimney.

6.Use 3 sheet metal screws at each joint to make the piping rigid.

7.It is recommended that no more than two (2) 90 degree bends be used in the stove pipe installation as more than two (2) may decrease the amount of draw and possibly cause smoke spillage.

NOTE: The chimney connector shall not pass through an attic, roof space, floor, ceiling, or similar concealed space. Where passage through a wall or partition of combustible construction is desired, the installation must conform with NFPA 211.

DRAFT REGULATOR

PIPE

FIG. 5

FLOOR PROTECTOR

CHIMNEY CAP MANDATORY

2 FT. MIN

10 FT.

3 FT. MIN.

 

PIPE REDUCER

11 FT. MINIMUM

NONCOMBUSTIBLE

CONSTRUCTIONIN ACCORDANCE WITH

BAROMETRICNFPA 211

DRAFT REGULATOR

PIPE

FIG. 6

FLOOR PROTECTOR

RIGHT

WRONG

WRONG

FIG. 7

5

Page 5
Image 5
United States Stove 1261 owner manual Operation of the Heater, Chimney Connection

1261 specifications

The United States Stove Company 1261 is a striking and efficient wood-burning stove designed to provide warmth and comfort to homes while embracing classic craftsmanship. This stove has been a favorite among homeowners and outdoor enthusiasts alike, offering a blend of traditional style and modern performance.

One of the standout features of the 1261 is its high efficiency. With a maximum output of 77,000 BTUs, this stove can heat spaces of up to 2,000 square feet, making it an ideal choice for both small and large rooms. The efficient design allows for longer burn times, reducing the need for frequent refueling. This not only enhances convenience but also contributes to a more sustainable heating method.

The 1261 utilizes advanced combustion technology, including an air wash system that keeps the glass door clean. This feature is particularly appreciated by users because it maintains a clear view of the mesmerizing flames without requiring constant cleaning. Additionally, the secondary combustion system maximizes efficiency by burning off gases and particulates that would otherwise escape unburned, thus providing more heat and reducing emissions.

Constructed from heavy-duty steel, the United States Stove 1261 boasts durability and longevity. The robust build ensures that the stove can withstand high temperatures while maintaining its structural integrity. Furthermore, the cast iron door not only adds to the stove’s classic aesthetic but also provides optimal airflow control, allowing users to adjust the heat output with precision.

The stove comes equipped with a variety of features aimed at maximizing user experience. An easy-to-use draft control allows for simple adjustments, ensuring that the fire burns at the desired intensity. The large firebox is designed to accommodate larger logs, promoting longer burn times and reducing the frequency of loading.

In terms of design, the United States Stove 1261 features a traditional look that can complement various home decors. Its compact size allows for versatile placement within any room, whether in a rustic cabin or a modern home. With its combination of efficiency, durability, and classic design, the United States Stove 1261 is a reliable choice for those seeking an effective heating solution. It stands as a testament to the craftsmanship and innovation that the United States Stove Company is known for, making it a great addition to any household.