WARNINGS/SAFETY INFORMATION CONTINUED
17.CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater serviced as it may not be operating properly.
18.This
19.Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above see level. Refer to the National Fuel Gas Code.
20.The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
21.The appliance must be isolated from the gas supply piping system be closing its equip- ment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
22.Do not use this gas fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
2020 SPECIFICATIONS
Natural Gas |
|
| Propane/LPG |
|
|
Manifold Pressure Setting: | 4" w.c. | Manifold Pressure Setting: | 10" w.c. | ||
Gas Inlet Pressure: | Maximum | Gas Inlet Pressure: | Maximum | 13" w.c. | |
| Minimum | 5" w.c. |
| Minimum | 11" w.c. |
|
| Gas Rate | Number | |
Model Number | Type | Max BTU/Hr | Min BTU/Hr | of Burners |
2020N | Manual | 20,000 | 14,000 | 1 |
2020L | Manual | 20,000 | 14,000 | 1 |
|
|
|
|
|
Controls - Main control has 3 positions:
1.OFF - All gas to the burner is shut off at the control
2.PILOT - Valve position to light/maintain a standing pilot
3.ON - Opens valve for gas flow to complete system.
Piezo Ignitor - allows ignition of the pilot without the use of matches or batteries
ON/OFF Switch - Operates gas flow to the burner
HIGH / LOW Control - Infinite control :
Rotate knob clockwise to LOW, counter clockwise to HIGH.
4