OPERATING INSTRUCTIONS, CONTINUED
LIGHTING INSTRUCTIONS
1.STOP! Read the safety information on the previous page.
2.Set the thermostat to lowest setting.
3.Turn off all electrical power and open the access door.
4.Push in gas control (B) slightly and turn
clockwise | to "OFF". |
5.Push "ON / OFF" switch to "OFF" posi-
PILOT LOCATION
TOP VIEW OF BURNER ASSEMBLY
tion.
A
B
D
C
If the knob does not pop up when re- leased, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn control knob to "OFF" and call your gas supplier.
9. | Turn valve knob clockwise | to "ON". |
10. | Wait about one minute then turn burner | |
| switch (D) to "ON". It will take a few |
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't smell gas, go on to the next step.
7.Depress knob (B) and turn gas control
knob counterclockwise to "Pilot".
8.Push in knob (B) all the way and hold in. Immediately light the pilot by pushing in on the piezo button (A). Continue to hold the control knob in for about one(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 8.
minutes for the thermopile located on top |
of the pilot to heat up. |
NOTE: If unit is equipped with remote
11.Adjust flame height with the
12.Turn on all electrical power to the appli- ance.
13.Close access door.
NOTE: It is normal for the new heater to give off some odor the first time it is burned. This is due to the curing of the paint and any undetec- ted oil from the manufacturing process.
It is recommended that you burn your new heater for at least two(2) hours the first time you use it. If optional fan kit is installed, leave it turned off for the break in period.
TURN OFF GAS TO APPLIANCE
1.Open access door.
2.Turn switch (D) to "OFF"
3.Unplug all electric power if service is to be performed.
4.Push in gas control knob slightly and turn clockwise to the "OFF" position.
5.Close access door.
16