Installation Clearances

Installation Clearances

It is extremely important that you respect required installation distances and that you respect local installation regulations. This is for your safety! The manufacturer is not responsible for the product, if it is not installed following these recommendations. These clearances may only be reduced by means approved by the regulatory authority.

One necessary precautions when installing a wood stove is to leave sufficient space between the stove (top, sides, back, front, and under stove pipes) and any other material that can catch fire.

A combustible surface is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics etc.) These surfaces are not limited to those that are visible and also include materials that are behind non-combustible materials. If you are not sure of the combustible nature of a material, consult your local fire officials.

 

3500, 3500PB

3700, 3700PB

 

Single Wall Connector Pipe

Single Wall Connector Pipe

A – Chimney Connector to backwall

15.5” (394 mm)

21.5” (546 mm)

B – Chimney Connector to sidewall

28” (711 mm)

29” (737 mm)

C – Chimney Connector to cornerwall

15” (381 mm)

21.5” (546 mm)

D – Unit to backwall

13” (330 mm)

17” (432 mm)

E – Unit to sidewall

20” (508 mm)

20” (508 mm)

F – Unit to cornerwall

7” (178 mm)

11.5” (292 mm)