CIRCUIT BOARD FUNCTIONS

CIRCUIT BOARD FUNCTIONS

START-UP SEQUENCE OF EVENTS

Once the control panel is turned to one of the five heat settings, a timer begins that will start, stop and continue operation of the American Harvest as a preset temperature is achieved.

COMPONENT

OPERATION START

OPERATION END

Exhaust Blower
Starts Immediately

Will continue until shutdown. Shutdown

 

 

will occur when the operating tempera-

 

 

ture is below 90 degrees.

 

 

 

Agitator

Three minutes after starting the agita-

Will continue intermittingly, has deter-

 

tor will begin to turn

mined by the “HEAT SETTING”, until

 

 

shutdown

 

 

 

Auger

Three minutes after starting the auger

The auger will continue at the feed rate

 

will begin to turn

specified by the “HEAT SETTING”.

 

 

NOTE: Safety switches, HI limit and

 

 

vacuum sensor, must be activated to

 

 

continue proper operation.

 

 

 

Room Fan

Begins when 110 degrees is reached.

Will continue to operate until the

 

 

AMERICAN HARVEST cools down to

 

 

below 90 degrees. This may take sev-

 

 

eral minutes up to an hour.

 

 

 

Automatic Shutdown

If after 15 minutes, the American

Should the timer expire before the

 

Harvest has not reached the preset

preset operating temperature is

 

operating temperature, the unit will

achieved, resetting the time is possible

 

begin to automatically shut down. This

by switching the control knob to the

 

will be evident by the green light on

“OFF” position and back on to one of

 

the control board flashing.

the “HEAT SETTINGS”.

 

 

 

Normal Operation

If after 15 minutes the preset operat-

Operation will continue until either the

 

ing temperature of 110 degrees is

AMERICAN HARVEST control knob is

 

achieved, normal operation will con-

turned to the “OFF” position, or the

 

tinue.

operating temperature falls below 90

 

 

degrees. At such time the AMERICAN

 

 

HARVEST will default to the “Auto-

 

 

matic Shut Down”.

 

 

 