FREESTANDING STOVE INSTALLATION REQUIREMENTS

FREESTANDING STOVE INSTALLATION REQUIREMENTS

Horizontal Exhaust Termination:

1)Locate proper position for the type “PL” wall thimble (F).

2)Use a saber saw or keyhole saw to cut a 7 1/4-inch diameter hole through the wall (E) for a 3-inch pipe. For a 4-inch pipe, cut an 8 1/4-inch hole. Install the wall thimble (F)in the hole. The size of hole opening will vary with brand of wall thimble.

3)Position stove approximately 12” from the wall on the noncombustible floor pad. Push the type “PL” pipe (B) through the wall thimble (D). Squeeze a bead of high temperature RTV silicone sealer (A) around the outside of the 3” diameter exhaust pipe approximately ½” from the stove back panel. Firmly push on a section of type “PL” pipe (B) until the inner pipe liner pushes up against the bead of RTV sealer. Don’t seal the entire 3” diameter pipe as you will not be able to disassemble the pipe at a later date. The bead of silicone will act as a gasket right on the end of the 3” pipe (B). Alternate Method: An approved type “PL” connector back clamp may be used to allow easy disconnect for mainte- nance. (The RTV sealant must be used in mobile home installation)

4)Push stove with pipe attached towards wall. Pipe (B) will go through the wall thimble (F). Be careful not to dislodge the thimble. Position stove not closer than 9” to the wall.

5)Install type “PL” termination cap (G) with rodent screen cap (optional) on outside end or pipe. Note: The end of the exhaust pipe must extend a minimum of 12 inches from the outside of the building. Rodent screen cannot be less than 3/8” opening mesh.

6)If installing with combustion air from outside, cut a separate hole through the wall for the fresh air tube (C). This tube must be 2” minimum diameter pipe. Connect outside air pipe inlet on stove. This tube must be terminated with a 90 degree elbow or hood.

Note: Always check dimensions on unit before cutting hole in wall

3’ Minimum

Vertical Pipe

Dimensional tolerance ±0.25”