United States Stove 6039T Trouble Shooting, Unplug stove before performing any maintenance

Models: 6039 6039T

1 24
Download 24 pages 6.55 Kb
Page 18
Image 18
TROUBLE SHOOTING

TROUBLE SHOOTING

Unplug stove before performing any maintenance

PROBLEM

 

CAUSE: Too rich air/fuel mixture

 

 

 

 

 

 

 

 

 

? Fire burns with a lazy, orange flame

 

9 Make sure glass door is shut and

9 Check inside stove and exhaust

and/or fuel builds up in the firepot.

 

sealed tightly. If not, adjust door

pipes for blockage. Tap inside

Glass may become dirty.

 

handle or replace gasket.

walls of firebox, clean behind

 

 

 

lower access plates (located on

 

 

9 Check ash dumps are in place and

the back inside wall, next to the

 

 

sitting flat to assure a proper seal.

firepot) clean firepot and firebox

 

 

9 Check that exhaust fan is running

vent holes above firebrick panel.

 

 

 

 

 

 

 

and venting properly. If not, check

9 Feed rate is too HI for fuel, reduce

 

 

connection and clean or replace.

heat setting.

 

 

 

 

9 Moisture content above 15%.

9 Inadequate

combustion air

 

 

Allow fuel to dry or mix with wood

available,

add

outside

 

 

pellets.

combustion air.

 

 

 

 

(Optional kit 67FAK)

 

 

 

 

 

 

 

? Fire goes out or stove shuts down.

 

CAUSE: Firepot burns out of fuel

 

 

Fuel may stop feeding.

 

 

 

 

 

 

9 Hopper empty, refill

9 The control board diagnostics will

 

 

 

 

 

illuminate the “A” for a Vacuum

 

 

9 Auger jams. Remove auger and

Switch error and illuminate “B” for

 

 

clean. (Auger jams can be a prob-

a Hi Limit error.

 

 

 

lem if poor quality fuel is used. Or

 

 

 

 

 

excessive fines (sawdust, corn

 

 

 

 

 

cobs or husk) are found in hopper.

 

 

 

 

 

Auger jams are evident when the

 

 

 

 

 

auger turns but no fuel is delivered.

 

 

 

 

 

 

 

 

 

? Fire goes out or stove shuts down.

 

CAUSE: Auger stops turning

 

 

Fuel may stop feeding.

 

 

 

 

 

 

9 Auger has come loose. Check to

9 Hi limit sensor. Evident when

 

 

 

 

see if auger motor is turning and

stove is extremely hot and the

 

 

auger is not. NOTE: Auger is held

light above “B” is flashing. Allow

 

 

to the auger motor by a coupler

stove to cool for 1 hour and

 

 

that is fastened to the auger motor.

restart.

 

 

 

 

Simply slide the auger into the

 

 

 

 

 

auger housing and rotate until it

9 Vacuum switch tripped. Caused

 

 

fits into the coupler.

by exhaust blower not running

 

 

 

or venting blocked. Check

 

 

9 Low limit sensor. If the operating

blower, clean or replace. Clean

 

 

temperature is too low the stove

venting of blockage.

 

 

 

will shut down.

9 Auger motor not operating.

 

 

 

 

 

 

Inspect connection and replace

 

 

 

if necessary.

 

 

 

 

 

 

 

 

NOTE: Negative pressure in a home is a serious issue. All American Harvest appliances should

be installed with the optional fresh air kit (67FAK).

18

USSC

Page 18
Image 18
United States Stove 6039T Trouble Shooting, Unplug stove before performing any maintenance, Problem, a Hi Limit error