United States Stove 6039T Circuit Board Functions, Start-Upsequence Of Events, Component, Auger

Models: 6039 6039T

1 24
Download 24 pages 6.55 Kb
Page 16
Image 16
CIRCUIT BOARD FUNCTIONS

CIRCUIT BOARD FUNCTIONS

START-UP SEQUENCE OF EVENTS

Once the control panel is turned to on, a timer begins that will start, stop and continue operation of the American Harvest as a preset temperature is achieved.

COMPONENT

OPERATION START

OPERATION END

Exhaust Blower
Starts Immediately

Will continue until shutdown. Shutdown

 

 

will occur when the operating tempera-

 

 

ture is below 90 degrees.

 

 

 

Agitator

Three minutes after starting the agita-

Will continue intermittingly, has deter-

 

tor will begin to turn

mined by the “HEAT SETTING”, until

 

 

shutdown

 

 

 

Auger

Three minutes after starting the auger

The auger will continue at the feed rate

 

will begin to turn

specified by the “HEAT SETTING”.

 

 

NOTE: Safety switches, HI limit and

 

 

vacuum sensor, must be activated to

 

 

continue proper operation.

 

 

 

Room Fan

Begins when 110 degrees is reached.

Will continue to operate until the

 

 

AMERICAN HARVEST cools down to

 

 

below 90 degrees. This may take sev-

 

 

eral minutes up to an hour.

 

 

 

Automatic Shutdown

If after 15 minutes, the American

Should the timer expire before the

 

Harvest has not reached the preset

preset operating temperature is

 

operating temperature, the unit will

achieved, simply reset the stove by

 

begin to automatically shut down.

pressing the “ON” buttton.

 

 

 

Normal Operation

If after 15 minutes the preset operat-

Operation will continue until either the

 

ing temperature of 110 degrees is

AMERICAN HARVEST control is to

 

achieved, normal operation will con-

the “OFF” position, or the operating

 

tinue.

temperature falls below 90 degrees. At

 

 

such time the AMERICAN HARVEST

 

 

will default to the “Automatic Shut

 

 

Down”.

Adjusting the Air/Fuel Mixture

The two adjustments necessary for proper air/fuel mixture are the combustion air/blower setting and the auger run time setting. These two adjustments are the basis for allowing this model the ability to burn many types of fuel in many different installations.

The auger run time adjustment is made by pressing the “A” button and adjusting the nine variables up or down as necessary. This allows the user ultimate control of the amount of fuel delivered. Increasing the number displayed, feeds more fuel and lowering the number deceases the fuel. When adjustments are needed for the Combustion air/blower, press “B” and adjust up or down as required. The adjustments made here are saved automatically and applied to all nine heat ranges. Even though all nine heat ranges are affected, the lower ranges are adjusted the most. These adjustments allow, “tweaking” your unit for maximum efficiency.

Note: On some models the “A” and “B” buttons are deactivated from the factory.

If activation of “A” and “B” is necessary

Step 1 turn unit “ON”.

Step 2 Press and hold the Blower “UP” arrow and the Heat range “DOWN” arrow at the same time for 5 seconds. In most cases, you will see the numbers displayed in the heat range window and blower window blink. Then release the buttons and press “A” or “B” buttons to check activation. When activated, pressing either button will display a light above that letter and display a single digit in the blower speed window. The heat range window will be blank. If not activated, repeat the Step 1.