INSTALLATION AND OPERATION
INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY.
CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE!
Leave your CO alarm plugged in
This CO alarm is intended for use in a standard, unswitched 120VAC wall outlet. It is not intended for use in extension cords, power strips or outlets controlled by a switch or dimmer. These may not provide continuous power to the unit. When fully powered, it samples the air continuously. A microchip inside the unit stores each reading and remembers the levels of CO it has been exposed to over time. The unit goes into alarm mode when it has been exposed to a "critical" level of CO (measured in parts per million or "ppm") within a specified time (measured in minutes).
PLUG THE ALARM INTO AN OUTLET
120 VAC, 60 Hz, 100 mA
This CO alarm should receive continuous electrical power. Do not plug this alarm into an outlet controlled by a dimmer or switch or ground fault circuit interrupter.
1.Plug the unit into a standard UNSWITCHED 120VAC outlet. The unit should be located where it can wake you if it alarms at night.
2.Make sure the green power "ON" LED is on continuously when you plug it in. The horn will "chirp" during power up or when power is restored after an outage.
Test alarm immediately following installation and weekly for proper operation by pushing the test button. The alarm will then test itself for proper operation and the red LED indicator will flash on two
OPERATION, TESTING & MAINTENANCE
OPERATION: The alarm is operating once the power is connected. When CO gas is sensed at a high level or at a low level for a lengthy period of time, the unit sounds a loud alarm which continues until the air is cleared, or the alarm is reset.
If the local alarm is
TESTING YOUR ALARM: Test alarm monthly for proper operation by pushing the test button. Release the button. The green LED will go off and the yellow LED will come on. The alarm will then test itself for proper operation and the red LED will flash on two
STANDBY CONDITION: The green LED is on and blinks off approximately every 20 seconds whenever AC power is turned on. The Display will only indicate CO readings higher than 30ppm (Model
ALARM CONDITION: The red LED flashes on and the unit emits a loud, pulsating alarm (4 short beeps, pause/4 short beeps, pause, until reset). The Display will show the current CO reading (Model
Page 5