Universal Metal Industries ULT2824, ULT2830 PART 2 Electrical Connection, Instructions, Hood

Models: ULT2820 ULT2836 ULT2830 ULT2824

1 6
Download 6 pages 54.62 Kb
Page 4
Image 4
PART 2 Electrical Connection

PART 2 Electrical Connection

WARNING!

Ensure that the power supply is disconnected before proceeding. Verify that the power supply matches the ratings found on the appliance data label before proceeding. The complete appliance must be properly grounded at all times when electrical power is applied. Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized. Failure to complete electrical connections properly may result in damaged or non-functional systems. Follow instructions carefully to ensure proper installation.

It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this appliance. The electrical installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this standard may be obtained from:

National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471

INSTRUCTIONS:

A 15 to 20 amp electrical service is recommended for proper electrical supply. Always observe local building codes. Always use a dedicated circuit. The Trade-Wind®hood is supplied with a 5.0 amp variable speed fan control.

Wire connections: (See Diagram Below)

There are 3 wires on the front panel that require connection.

BLACK 120 VAC from electrical panel (usually black)

WHITE Neutral from electrical panel (white)

GREEN Ground from electrical panel (usually green)

CAUTION:

The neutral wire (white) must only be connected to the white neutral wire coming in from the electrical panel.

House Electrical

Panel

Green

White

120V Black (L)

Hood

BLK

WHT

GRN

Item No. 0AL00-UL-001 Revised 02/02/06 Copyright (C) 2006, Universal Metal Industries, Inc. Page 4

Page 4
Image 4
Universal Metal Industries ULT2824, ULT2830 PART 2 Electrical Connection, Instructions, House Electrical Panel, Hood