FCC PART 15 RADIO FREQUENCY DEVICES

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

--Reorient or relocate the receiving antenna.

--Increase the separation between the equipment and receiver.

--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

--Consult the dealer or an experienced radio/TV technician for help.

CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)

"Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows. A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of the bedrooms), and heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages.

OPERATIONAL SUMMARY

CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION

HORN

RED LED

SOLUTION / RECOMMENDATION

Silent

Blinks On once

DC Power is present.

 

approx every

 

 

40-45 seconds

 

3 Beeps,

Blinks On approx

Originating smoke alarm - If hazard is identified, please take

2 second pause,

every 2 seconds

all precautions if an alarm sounds by calling an Emergency

Repeat

 

Service and getting out of the home.

3 Beeps,

Blinks On approx

Nuisance Alarm - If there is no hazard present, verify the

2 second pause,

every 2 seconds

alarm is mounted in the correct location (see User's Manual,

Repeat

 

"AVOID THESE LOCATIONS" section). Reset alarm as

 

 

instructed below.

3 Beeps,

Blinks On approx

Silence Feature is activated by pressing and releasing the

2 second pause,

every 2 seconds

Test/Silence button on the initiating alarm while in alarm

Repeat

 

condition. Silence mode will last for 8-12 minutes.

 

 

 

Silent

Blinks On once

QUICK FIND® Alarm Origination - To initiate QUICK FIND®, press

(alarmed

approx every

the Test/Silence button on any alarm; and, after releasing the button,

previously)

40-45 seconds

the originating alarm will continue to sound for approx 60 seconds.

 

(normal operation

Reset the originating alarm.

 

mode) or Blinks on

 

 

once approx every

 

 

10 seconds

 

 

(silence mode)

 

Silent

Blinks On once

To Reset the Alarm - Hold the Test/Silence button for 10

 

approx every

seconds, or temporarily remove (and then replace) the battery.

 

40-45 seconds (normal

This will clear alarm origination and clear Silence mode. Reset

 

operation mode) or

after each smoke alarm event.

 

Blinks On once approx

 

 

every 10 seconds

 

 

(silence mode)

 

 

 

 

1 Chirp every

Blinks On once

Low Battery - Check to make sure the battery activation pull-

40 seconds

approx every

tab has been completely removed, battery polarity is correct

 

40-45 seconds

and the battery terminals are making contact with the smoke

 

 

alarm contacts in the battery drawer. If chirp continues,

 

 

replace the 9V battery (see User's Manual for recommended

 

 

battery types).

 

 

 

3 Beeps approx

Blinks On once

Trouble/Service Alarm. Replace Alarm.

every 40 seconds

approx every

 

after LED flashes

40-45 seconds

 

 

 

 

1 Beep

Blinks On once

End-of-Service Life alarm. The alarm should be replaced

approx every

approx every

immediately.

60 seconds

40-45 seconds

 

 

 

 

Page 8