3741801
PAGE 26
REV: 15, July 2003
RATINGS, DATA, AND DIMENSIONS
NATURAL GAS STEAM BOILERS
| *A.G.A | Heating | Net I=B=R** | Gas |
|
| Dimensions |
|
| WATER CONTENT |
| Annual Fuel | ||||||
Boiler | Input | Capacity | Steam Rating | Inlet |
|
|
|
|
|
|
| (GALLON CAPACITY) | Utilization Efficiency | |||||
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Number | Btu/Hr. | Btu/Hr. |
|
| Size | A | B | C | D | E | F | G |
|
|
|
| (AFUE) | |
Btu/Hr. | Sq. Ft. | To Water | To LWCO |
| ||||||||||||||
& Damper | & Damper |
|
|
|
|
|
|
|
|
|
|
| Line | Line |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Elect Ign | Std. Pilot | |||||
PEG112C | 112,500 | 90,000 | 67,500 | 281 | 1/2 | 14.1/4 | 27.5/8 | 24.1/8 | 5 | 3.1/2 | 6 | 44.3/4 | 4.8 | 3.0 |
| 81.0 | 78 | |
PEG150C | 150,000 | 120,000 | 90,000 | 375 | 1/2 | 17.1/8 | 28.5/8 | 24.5/8 | 6 | 4 | 6.1/2 | 45.1/4 | 6.0 | 3.7 |
| 81.0 | 78 | |
PEG187C | 187,000 | 151,000 | 113,300 | 472 | 1/2 | 20 | 29.5/8 | 25.1/8 | 7 | 4.1/2 | 7 | 45.3/4 | 7.0 | 4.4 |
| 81.0 | 78 | |
PEG225C | 225,000 | 181,000 | 135,800 | 556 | 3/4 | 22.13/16 | 30.5/8 | 25.5/8 | 8 | 5 | 8 | 46.3/4 | 8.4 | 5.0 |
| 81.0 | 78 | |
PEG262C | 262,500 | 212,000 | 159,000 | 663 | 3/4 | 25.5/8 | 30.5/8 | 25.5/8 | 8 | 5 | 8 | 46.3/4 | 9.5 | 5.8 |
| 81.0 | 78 | |
PEG300C | 299,999 | 243,000 | 182,300 | 760 | 3/4 | 28.1/8 | 31.5/8 | 26.1/8 | 9 | 5.1/2 | 10 | 48.3/4 | 10.7 | 6.4 |
| 81.0 | 78 |
NOTE: For altitudes above 2,000 ft. ratings should be reduced at the rate of 4% for each 1,000 ft. above sea level, The MEA number for the PEG series is
Electrical service to be 120 Volts, 15 Amps, 60 Hz.
**For equivalent square feet of radiation, divide I=B=R output by 240.
STANDARD EQUIPMENT: Crafted Boiler, Drafthood, Low Water
OPTIONAL EQUIPMENT: Electronic water feeder
The Ratings marked “Net I=B=R” indicate the amount of equivalent direct cast iron radiation each boiler will take care of under normal conditions and thermostatic control. The Net I=B=R Steam Ratings shown are based on a piping and pickup allowance of 1.333. Proper allowance has been made for piping and pickup in accordance with the factors shown in the I=B=R Standard as published by The Hydronics Institute.
Selection of boiler size should be based upon Net BTU per Hour of the connected radiation and piping.
The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. In line with it's policy of product improvement, Utica Boilers reserves the right to make changes without notice.
LEFT SIDE VIEW | FRONT VIEW | RIGHT SIDE VIEW |