Utica PEG-C Ratings, Data, And Dimensions, Natural Gas Steam Boilers, Left Side View, Front View

Models: PEG-C

1 28
Download 28 pages 48.75 Kb
Page 28
Image 28
RATINGS, DATA, AND DIMENSIONS

3741801

PAGE 26

REV: 15, July 2003

RATINGS, DATA, AND DIMENSIONS

NATURAL GAS STEAM BOILERS

 

*A.G.A

Heating

Net I=B=R**

Gas

 

 

Dimensions

 

 

WATER CONTENT

 

Annual Fuel

Boiler

Input

Capacity

Steam Rating

Inlet

 

 

 

 

 

 

 

(GALLON CAPACITY)

Utilization Efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

Btu/Hr.

Btu/Hr.

 

 

Size

A

B

C

D

E

F

G

 

 

 

 

(AFUE)

Btu/Hr.

Sq. Ft.

To Water

To LWCO

 

& Damper

& Damper

 

 

 

 

 

 

 

 

 

 

 

Line

Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elect Ign

Std. Pilot

PEG112C

112,500

90,000

67,500

281

1/2

14.1/4

27.5/8

24.1/8

5

3.1/2

6

44.3/4

4.8

3.0

 

81.0

78

PEG150C

150,000

120,000

90,000

375

1/2

17.1/8

28.5/8

24.5/8

6

4

6.1/2

45.1/4

6.0

3.7

 

81.0

78

PEG187C

187,000

151,000

113,300

472

1/2

20

29.5/8

25.1/8

7

4.1/2

7

45.3/4

7.0

4.4

 

81.0

78

PEG225C

225,000

181,000

135,800

556

3/4

22.13/16

30.5/8

25.5/8

8

5

8

46.3/4

8.4

5.0

 

81.0

78

PEG262C

262,500

212,000

159,000

663

3/4

25.5/8

30.5/8

25.5/8

8

5

8

46.3/4

9.5

5.8

 

81.0

78

PEG300C

299,999

243,000

182,300

760

3/4

28.1/8

31.5/8

26.1/8

9

5.1/2

10

48.3/4

10.7

6.4

 

81.0

78

NOTE: For altitudes above 2,000 ft. ratings should be reduced at the rate of 4% for each 1,000 ft. above sea level, The MEA number for the PEG series is 17-79.

Electrical service to be 120 Volts, 15 Amps, 60 Hz.

**For equivalent square feet of radiation, divide I=B=R output by 240.

STANDARD EQUIPMENT: Crafted Boiler, Drafthood, Low Water Cut-off (Probe Type), Deluxe Jacket, Wiring, Automatic Vent Damper, Ported Stainless Steel Burners, Blocked Vent and Roll-Out Safety Switches, Gas Valve, Pilot, Pressure High Limit Control, 2-2" Supply Tapping-L.H. Plugged, 2-2" Return Tappings-L.H. Plugged. Packed in Separate Carton:Pop Safety Valve and Boiler Drain.

OPTIONAL EQUIPMENT: Electronic water feeder

The Ratings marked “Net I=B=R” indicate the amount of equivalent direct cast iron radiation each boiler will take care of under normal conditions and thermostatic control. The Net I=B=R Steam Ratings shown are based on a piping and pickup allowance of 1.333. Proper allowance has been made for piping and pickup in accordance with the factors shown in the I=B=R Standard as published by The Hydronics Institute.

Selection of boiler size should be based upon Net BTU per Hour of the connected radiation and piping.

The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. In line with it's policy of product improvement, Utica Boilers reserves the right to make changes without notice.

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

Page 28
Image 28
Utica PEG-C Ratings, Data, And Dimensions, Natural Gas Steam Boilers, Left Side View, Front View, Right Side View