INSTALLation

Continued

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 22).

IMPORTANT: Install equipment shutoff valve in an accessible location. Equipment shutoff valve is for turning on or shutting off gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

2.Remove screws that attach branch sup- port to fireplace (see Figure 23). Carefully lift up branch support and remove from fireplace (see Figure 23).

3.Route flexible gas line included from fire- place control to equipment shutoff valve through side or rear access holes in outer casing.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility fromthefireplace(seeFigure23). The flexible gas supply line connection to the equipment shutoff valve should be accessible.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

4. Apply pipe joint sealant lightly to male

PROPANE/LP

From External Regulator (11" W.C. to 14" W.C. Pressure)

NATURAL

threads of gas connector attached to flex-

ible gas line/equipment shutoff valve (see

Figure 24, page 18).

5. Check all gas connections for leaks. See

Checking Gas Connections, page 18.

3" Minimum

From Gas Meter (5" W.C. to 10.5" W.C.

Pressure)

Branch Screen

Shoulder

Screw

Pipe Cap Nipple

Tee

Joint

Support Shipping

Screw

Sediment Trap

Figure 22 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer.

CONNECTING Equipment shutoff valve to heater control

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.To remove fireplace screen, remove 2 screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fire- place screen up and pull out to remove.

Flexible

Gas Line

Screen

Figure 23 - Removing Log Base

Assembly From Fireplace

113111-01H

www.desatech.com

17