Vanguard Heating GVB35P, GVB50P Technical Service, Service Hints, Specifications

Models: GVB50P GVB35P

1 40
Download 40 pages 51.54 Kb
Page 33
Image 33
TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

35,000 BTU/Hr

50,000 BTU/Hr

 

Model

Model

BTU

35,000

50,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

10.5" W.C.

10.5" W.C.

Inlet Gas Pressure

 

 

Maximum

14" W.C.

14" W.C.

Minimum

11" W.C.

11" W.C.

Dimensions, Inches

 

 

Heater (H x W x D)

25 x 27 1/4 x 16

28 x 32 1/2 x 16

Shipping Weight (pounds)

78

98

Flue Vent Size

4" dia.

4" dia.

Orifice Size

52 drill, ø .0635

46 drill, ø .081

Note: These heaters are certified for elevations of 0-4500 feet above sea level. For elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce yellow flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.