OM-279 Page 9
SECTION 2 INSTALLATION

2-1. Specifications

Model
Amperes Input at Rated Load
Output 60 Hz Type of Plasma Rated Rated
Cutting
Maximum
Open-
CircuitModel
200 V 230 V 460 V 575 V KVA KW Output Gas Output Cutting
Capacity Circuit
Voltage
DC
Single-
Phase 42.30
(3.40*) 36.80
(2.95*) 18.40
(1.50*) –– 8.49
(0.68*) 6.55
(0.20*) Direct
Current, Air Or 50 A @
110 Volts 0.7 in
3-Phase –– 18.40
(2.13*) 9.20
(1.07*) 7.40
(0.85*) 7.32
(0.85*) 6.60
(0.32*)
Straight
Polarity
(DCEN)
Nitrogen
Only
110 Volts
DC, 60%
Duty Cycle
(18 mm)
At 10 IPM 280
*While idling

2-2. Dimensions And Weight

CDimensions
A36-3/4 in (934 mm)
B24-1/2 in (622 mm)
C21 in (533 mm)
A
Weight
A
Single-Phase Models: 147 lb (66 kg)*
Three-Phase Models: 168 lb (76 kg)*
Ref. ST-801 454-B
B*Without Torch
6 Minutes Cutting 4 Minutes Resting

2-3. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before cutting.
YExceeding duty cycle can
damage unit and void war-
ranty.
60% Duty Cycle
Overheating
0
15

A

OR
Reduce Duty Cycle
Minutes duty1 4/95