SECTION 3 – OPERATION

3-1. Front Panel Controls

4 7

2

3

5

6

 

 

 

 

 

 

 

 

 

 

 

 

1

Ref. ST-190 676

1 Pilot Arc Switch

Use switch to control pilot arc.

Place switch in Expanded Metal position for continuous pilot arc. Use while cutting ex- panded metals only.

.The Expanded Metal position keeps the pilot arc in the circuit at all times. Life of consumables will be significantly re- duced while in Expanded Metal mode.

Place switch in Tip Saver position to provide pilot arc output for arc starting only. Use Tip

Saver position in most applications to length- en the life of the torch and its consumables, and to obtain maximum cutting performance.

Torch trigger must be reset after every cut while in Tip Saver mode.

2Gas/Air Pressure Gauge

3Output Control

Use control to select cutting output in am- peres. Gas/air automatically flows at the set pressure.

Use Gas/Air Set area of control range for set- ting gas/air pressure (see Section 3-2).

4Trouble Lights (see Section 4-2)

5Ready Light

Ready light comes On when unit is On to indi- cate that all safety shutdown systems are okay. If Ready light does not come On, check trouble lights.

6Power Light

7Power Switch

OM-279 Page 14

Page 18
Image 18
Hobart Welding Products OM-279 manual Operation, Front Panel Controls