2-6. Connecting Gas/Air Supply
Use only clean and dry gas/air with 70 to 150 psi
1 Unit Gas Fitting (Female 1/4
(483 to 1034 kPa) pressure.
NPT)
| 2 | Quick Connect Gas Fitting | |
1 | 3 | Standard Gas Fitting | |
| |||
| Obtain and install desired fitting. | ||
| 4 | Hose | |
2 | Obtain suitable hose according to | ||
| installed fitting, and connect to fit- | ||
| ting. Route hose to gas/air supply. | ||
| Adjust gas/air pressure according | ||
| to Section | ||
3 | Y Incorrect plasma gas can | ||
4 | From Gas/Air Supply | cause torch and power | |
source damage. Use only air | |||
| |||
|
| ||
|
| or nitrogen for the plasma | |
|
| gas. |
Ref.
2-7. Installing And Connecting Work Clamp
3
2
1
1Work Cable From Unit
2Ring Terminal
3Screw
4Work Clamp Handle
Connect ring terminal end of cable to handle using screw.
Connect work clamp to a clean,
4
Tools Needed:
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
| ||||||||
|
|
|
|
|
|
|
| |
Input Voltage | 200 | 230 | 460 | 230 | 460 |
| 575 | |
|
|
|
|
|
|
|
| |
Input Amperes At Rated Output | 42.3 | 36.8 | 18.4 | 18.4 | 9.2 |
| 7.4 | |
|
|
|
|
|
|
|
| |
Max Recommended Standard Fuse Or Circuit Breaker Rating In | 60 | 60 | 30 | 30 | 15 |
| 10 | |
Amperes |
| |||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Min Input Conductor Size In AWG/Kcmil | 8 | 10 | 14 | 14 | 14 |
| 14 | |
|
|
|
|
|
|
|
| |
Max Recommended Input Conductor Length | 110 (33) | 97 (29) | 153 (47) | 66 (20) | 266 (81) | 415 | ||
In Feet (Meters) | (127) | |||||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
Min Grounding Conductor Size In AWG/Kcmil | 10 | 10 | 14 | 14 | 14 |
| 14 | |
|
|
|
|
|
|
|
| |
Reference: 1993 National Electrical Code (NEC) |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|