![Connections, page 17)](/images/new-backgrounds/51960/5196053x1.webp)
TROUBLE- SHOOTING
Continued
WARNING
WARNING ICON | G 001 |
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
| OBSERVED | POSSIBLE |
|
|
|
|
| |
| PROBLEM | CAUSE | REMEDY | |||||
|
|
|
|
|
|
|
| |
| Fireplace produces a | 1. | Metal expanding while | 1. | This is common with | |||
| clicking/ticking noise |
| heating or contracting |
| most fireplaces. If noise | |||
| just after burner is lit |
| while cooling |
| is excessive, contact | |||
| or shut off |
|
|
| qualified service person | |||
|
|
|
|
|
|
| ||
| Fireplace produces | 1. | Fireplace burning vapors | 1. | Ventilate room. Stop | |||
| unwanted odors |
| from paint, hair spray, |
| using odor causing | |||
|
|
| glues, etc. (See IMPOR- |
| products while fire- | |||
|
|
| TANT statement above) |
| place is running | |||
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | |||
|
|
| ing statement at |
| leaks (see Checking Gas | |||
|
|
| top of page |
| Connections, page 17) | |||
|
|
|
|
|
|
| ||
| Fireplace shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or | |||
| use (ODS operates) |
| available |
| door for ventilation | |||
|
| 2. | Low line pressure | 2. | Contact local natural | |||
|
| 3. | ODS/pilot is partially |
| gas company | |||
|
| 3. | Clean ODS/pilot (see | |||||
|
|
| clogged |
| Cleaning and Mainte- | |||
|
|
|
|
| nance, page 24) | |||
|
|
|
|
|
|
| ||
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all | |||
| control knob is in |
| ing statement at |
| leaks (see Checking Gas | |||
| OFF position |
| top of page |
| Connections, page 17) | |||
|
| 2. | Control valve defective | 2. | Replace control valve | |||
|
|
|
|
|
|
| ||
| Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing | |||
| combustion |
| tween control valve |
| and remove foreign | |||
|
|
| and burner |
| matter | |||
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | |||
|
|
| ing statement at |
| leaks (see Checking Gas | |||
|
|
| top of page |
| Connections, page 17) | |||
|
|
|
|
|
| |||
| Moisture/condensa- | 1. | Not enough combus- | 1. Refer to Air for Combus- | ||||
| tion noticed on |
| tion/ventilation air. |
| tion and Ventilation re- | |||
| windows |
|
|
| quirements | |||
|
|
|
|
| (page 6) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 27 | ||
|
|
|
|
|
|
|
|
|
102885