Whirlpool UXT2030AY Venting Requirements, Installation Clearances, Cold Weather Installations

Models: W10400320B

1 28
Download 28 pages 62.56 Kb
Page 5
Image 5
Installation Clearances

Installation Clearances

C

B

D

A

E

A. 18" (45.7 cm) min. clearance - upper cabinet to countertop

B. 18" (45.7 cm) to 24" (61.0 cm) suggested max. - bottom of range hood to cooking surface

C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm) models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm) models

D. 13" (33.0 cm) cabinet depth

E. 36" (91.4 cm) base cabinet height

Venting Requirements

Vent system must terminate to the outdoors.

Do not terminate the vent system in an attic or other enclosed area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use a 7" (17.8 cm) round metal vent. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps or duct tape to seal all joints in the vent system.

The vent system must have a damper.

Use caulking to seal exterior wall or roof opening around the cap.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

Venting Methods

Vent system can terminate either through the roof or wall. Use 7" (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.

NOTE: Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.

Roof Venting

Wall Venting

B

A

C

A

B

C

 

A. 7" (17.8 cm) round vent

A. 7" (17.8 cm) round vent out

through roof

the top and through the wall

(purchased separately)

(purchased separately)

B. Roof cap with damper

B. Wall cap with damper

(purchased separately)

(purchased separately)

C. 18"

(45.7 cm) min. to

C. 18"

(45.7 cm) min. to

24"

(61.0 cm) max. above the

24"

(61.0 cm) max. above the

cooking surface

cooking surface

5