SAFETY INFORMATION

Continued

WARNINGS Continued

WARNING: Any change to this heater or its controls can be dangerous.

1.Use only natural gas. Do not convert heater to use different fuel type.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This heater shall not be installed in a bedroom or bathroom (VN12A - input 12,000 BTUs).

4.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

5.Always run heater with control knob at LOW or HIGH locked positions (VN12A) or ON position (VN6B). Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.

6.This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combus- tion and Ventilation, pages 5 through 8.

7.Never run heater in small, closed room. Open door into next room to help ventilate.

8.Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

9.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

10.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

11.Never place any objects on the heater.

12.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching.

13.Carefully supervise young children when they are in same room with heater.

14.Make sure grill guard is in place before running heater.

15.Do not use heater if any part has been under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

17.Operating heater above elevations of 4,500 feet may cause pilot outage.

3

100845

Page 3
Image 3
Vanguard Heating VN6B, VN12A installation manual Safety Information

VN6B, VN12A specifications

The Vanguard Heating VN6B and VN12A represent cutting-edge solutions in residential heating technology. Designed to meet a variety of heating needs, these systems combine efficiency and user-friendly features, catering to an increasingly eco-conscious market.

The VN6B model is ideal for smaller homes or spaces, boasting a compact design without sacrificing power. It uses advanced condensing technology, which allows it to achieve impressive efficiency ratings. With an Annual Fuel Utilization Efficiency (AFUE) of up to 96%, the VN6B maximizes heat output while minimizing fuel consumption. This leads to significant cost savings on heating bills, making it an attractive choice for homeowners looking to upgrade their heating systems.

Meanwhile, the VN12A is built for larger areas, providing robust heating solutions for bigger residential spaces. With similar condensing technology, it features an AFUE rating that matches its smaller counterpart, ensuring that it also operates with remarkable efficiency. The VN12A is engineered with a modulating burner, which adjusts the flame size according to the building’s heating needs. This means it can operate quietly and smoothly, offering comfort without the jarring temperature fluctuations that other systems may create.

Both models incorporate innovative safety features, including a built-in flue gas condensation sensor that ensures safe operation under varied conditions. Additionally, they include a user-friendly digital thermostat, which enables precise temperature control and can be programmed for optimal efficiency. Homeowners can easily customize their heating schedule, making it convenient to maintain a comfortable living environment while also conserving energy.

Another notable characteristic of the Vanguard VN6B and VN12A is their durable construction. Made from high-quality materials, these heating units are designed to withstand wear and tear, ensuring a long lifespan with minimal maintenance. Regular maintenance reminders are a feature, making it straightforward for homeowners to keep track of service needs.

In summary, the Vanguard Heating VN6B and VN12A models stand out in the market for their exceptional efficiency, smart technologies, and user-centric features. They are excellent choices for homeowners seeking reliable and environmentally friendly heating solutions that promise comfort year-round, all while keeping energy costs low.