10

INSTALLING

NOTICE

A qualified service person must install stove. Follow all local codes.

WARNING

WARNING ICON

G 001

Never install the stove

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the stove

in high traffic areas

in windy or drafty areas

CAUTION

WARNING ICON

G 001

Log heaters installed in this stove create warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove where impuri- ties in the air (such as tobacco smoke) exist, may discolor walls.

CAUTION

WARNING ICON

G 001

Only open and close door with the handle at the bottom of the door.

IMPORTANT: Vent-free gas log heaters add moisture to the air. Although this is benefi- cial, installing stove in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 6 through 9.

IMPORTANT: Make sure the stove is level. If stove is not level, log set will not work properly.

INSTALLATION CLEARANCES

WARNING

WARNING ICON

G 001

Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling Clearances

A.Clearances from the back of stove to wall should not be less than 3 inches (see Figure 6).

3"

Figure 6 - Minimum Clearance to Back Wall

103661