®

UNVENTED (VENT-FREE)

PROPANE/LP GAS LOG HEATER

VARIABLE MANUALLY-CONTROLLED MODELS ALSO

DESIGN-CERTIFIED AS VENTED DECORATIVE APPLIANCES

OWNER’S OPERATION AND INSTALLATION MANUAL

FLAME-MAX®

Models VYS18PWA,

VYS24PWA, and

VYS30PWA (Millivolt)

Remote Ready

AUTO OFF ON

HI

LO

N

O

TOL

O F F

I

Patent Pending

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa- tion and operational procedures. For as- sistance or additional information con- sult a qualified installer, service agency, or the gas supplier.

WARNING: This appliance is for installa- tion only in a solid-fuel burning masonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design certified for these installations in accor- dance with ANS Z21.11.2. Exception: Do not install this appliance in a factory- built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Page 1
Image 1
Vanguard Managed Solutions VYS24PWA, VYS30PWA installation manual OWNER’S Operation and Installation Manual

VYS30PWA, VYS24PWA specifications

Vanguard Managed Solutions, particularly the VYS30PWA and VYS24PWA models, represent advanced innovations in the field of managed solutions. These models cater to diverse industries, providing scalable and efficient operational frameworks.

The VYS30PWA model is characterized by its robust performance and adaptability. It is designed to handle complex workloads with ease, making it suitable for environments where efficiency and reliability are paramount. The backbone of this unit is its high-capacity processing power, which allows it to support multiple simultaneous operations without significant lag. This is particularly beneficial for organizations that require real-time data processing and analytics capabilities.

On the other hand, the VYS24PWA model offers a more compact solution without compromising on performance. This model is ideal for smaller enterprises or specific project setups where space is limited but functionality cannot be sacrificed. It ensures optimal resource usage while maintaining high-speed connectivity and data flow. Its design enables seamless integration with existing systems, reducing the need for extensive modifications.

Both models incorporate cutting-edge technologies such as cloud integration and advanced analytics. The cloud capability allows users to leverage a flexible workspace, where data and applications can be accessed from any location, fostering remote collaboration and improving productivity. Furthermore, by utilizing cloud-based analytics, organizations can gain actionable insights into their operations, driving informed decision-making.

Security is also a top priority for Vanguard Managed Solutions. Both the VYS30PWA and VYS24PWA feature advanced encryption protocols and are equipped with state-of-the-art security measures to safeguard sensitive information. This focus on security ensures that businesses can operate with peace of mind in an increasingly digital landscape.

In terms of characteristics, both models are built with user-friendliness in mind. Their interfaces are designed to facilitate easy navigation, ensuring that employees can quickly adapt and utilize the systems effectively. Additionally, support and maintenance options are built into the package, allowing organizations to benefit from ongoing assistance as needed.

Overall, Vanguard Managed Solutions VYS30PWA and VYS24PWA are tailored to meet the evolving needs of modern businesses. With a combination of power, versatility, and security, they stand out as essential tools for organizations looking to streamline their operations and enhance overall productivity.