INSTALLING GWMS2 (OPTIONAL) WALL MOUNTED SWITCH

OWNER’S MANUAL

INSTALLATION

Continued

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package).

INSTALLING GWMS2 (OPTIONAL) WALL MOUNTED SWITCH

Items Included for Installation

Switch

Switch Cover (With Screws)

25 Ft. Wire

CONNECTING TO GAS SUPPLY

Items Included for Installation WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Flexible Gas Hose (if allowed by local codes)

Fitting

Figure 11 - Attaching Flexible Gas Hose to Heater

Masonry Screw

I

H

I

H

 

O

NO

FF

Mounting

Flanges

Figure 12 - Attaching Base Assembly to Fireplace Floor

Connecting To Log Set

1.Connect one terminal of 25 ft. wire to bottom contact of switch located on heater front control panel (see Figure 13).

2.Connect remaining wire terminal to the “TH” terminal on the control valve (see Figure 13).

3.Route the 25 ft. wire to a convenient location.

CONNECTING TO GAS SUPPLY WARNING: Do not connect the switch to a power source. Electrical shock and/or fire haz- ard will occur.

IMPORTANT: The wire may be shortened but must not be lengthened.

4.Connect one bare wire end to each of the terminals of the provided wall switch.

5.Install the wall switch and cover in the wall.

Switch

AUTOConnecting To Log Set

OFF

ON

One

 

terminal

To Wall

of 25 ft.

Switch

wire

 

To Wall

Switch

Wall Switch

Figure 13 - Connecting Wire Terminals

Manual backgroundWARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

Manual background CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer, see above)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connec- tion. Purchase the optional CSA/AGA de- sign-certified equipment shutoff valve from your dealer. See Accessories, page 24.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 14, page 12. Pointing the vent down protects it from freezing rain or sleet.

Continued

105190

11

Page 11
Image 11
Vanguard Managed Solutions VYS24PWA INSTALLING GWMS2 OPTIONAL WALL MOUNTED SWITCH, Connecting To Gas Supply, Installation