Operation (Continued)

Dayton Operating Instructions and Parts Manual

Model 4W315C

Operation (Continued)

BLEEDING FUEL LINE

1.Loosen fuel line clamp and remove fuel line from engine. Place open end of fuel line over a clean container to catch any fuel spilled in step 3, below.

O

S

Fuel Valve

Lever

Figure 18 - Fuel Valve Lever In “O” (open) Position

Decompression Lever

2.Move fuel valve lever to the “O” (open) position (See Figure 18).

3.Allow air to bleed from line. When fuel exits fuel line in a steady stream, reattach fuel line to engine.

4.Add spilled fuel back into fuel tank.

3.Move engine run lever to the RUN position (See Figure 19).

Engine Run

Lever

Figure 20 - Decompression Lever

STARTING

Never use gaso- line, paint thinner,

or any other flammable liquid as a starting aid. An explosion may occur.

IMPORTANT: The engine speed is preset. The throttle is locked in preset position. Do not adjust throttle. Preset position lets engine run at 3600 RPM under load. The engine must maintain 3600 RPM for generator to create correct voltage. Running engine at lower speeds will damage generator and powered items.

IMPORTANT: Never start generator with electrical loads connected. Start engine before adding electrical loads.

1.Make sure fuel tank is full. See “Fuel,” page 8 for fuel information.

2.Move fuel valve lever to the “O” (open) position (See Figure 18).

RUN

STOP

Figure 19 - Engine Run Lever

You must fully move engine run/

stop knob to the RUN position to run engine at 3600 RPM. Do not run engine at lower speeds. Running engine at lower speeds will damage generator and powered items.

4.Start the engine. a. Electric Starter

(1)Slowly pull starter rope until you feel strong resistance. Gently return starter rope to engine.

(2)Push decompression lever all the way down (See Figure 20). Decom- pression lever will stay in this position until you turn starting key.

(3)Turn the starting key clockwise to the START position (See Figure 21). Hold it there until engine starts.

Starting Key

OIL

CHARGE

OFF

Figure 21 - Starting Key

(4) When engine starts, release key.

IMPORTANT: Do not use electric starter more than ten seconds. Starter motor damage may occur. If engine fails to start, release the key and wait 15 seconds. After 15 seconds, try starting again.

®

107358

13

Version B - For Reduction

G016.J

Page 13
Image 13
VDO Dayton operating instructions Operation Continued, Starting, Model 4W315C