Assembly (Continued)

Dayton Operating Instructions and Parts Manual

4W315C

Dayton® Diesel Electric Generator

Assembly (Continued)

2.Locate the red, positive (+) battery cable from starter solenoid. Connect it to the positive (+) battery terminal (See Figure 13).

3.Locate the black, negative (–) battery cable attached to engine block. Connect it to the negative (–) battery terminal (See Figure 13).

Do not overfill fuel tank. Always allow room for fuel to expand. If you overfill tank, fuel can overflow onto hot engine. This can cause fire. After refueling, tightly close fuel tank cap.

Do not spill fuel. If fuel spills, make sure area is dry before starting engine.

Never smoke in refueling area. Never allow open flames or sparks in area.

ENGINE OIL Black, Negative (–) Installation Battery Cable

4.Check battery before starting engine. Make sure fluid levels are full. Make sure battery is charged.

See engine owner’s manual for more information.

Red, Positive Cable

From Starter Solenoid

Store fuel in approved container. Store fuel in a well-vented area free of open flames or sparks.

Use clean, fresh, diesel fuel. Use diesel fuel with cetane rating of 45 or higher. Avoid getting dirt, dust, or water in fuel tank. See engine owner’s manual for more information.

Figure 11 – Connecting Black, Negative (–) Battery Cable to Engine Block

MOUNTING BATTERY TO GENERATOR

1.Secure battery to generator by battery hold-down system. This system consists of the battery mounting bracket, hook bolt, and nut (See Figure 12).

Battery Mounting

Nut

Bracket

 

BatteryFUELManual background Hook Bolt

Figure 12 – Battery Hold-Down System

 

ENGINE OIL

 

We ship the generator without oil in the

 

engine crankcase. You must add oil before

 

starting engine. See “Engine Lube Oil,”

 

page 9 for specific oil type.

 

CHECKING OIL LEVEL AND ADDING OIL

 

Follow steps below to check oil level.

 

Make sure engine is level and stopped.

Black, Negative

1. Remove dipstick (See Figure 14). Wipe

dipstick clean.

Cable From

Engine Block

2. Insert dipstick into oil filler neck. Do not

 

 

screw it in. Oil level should be at top of

Figure 13 – Connecting Positive and

filler neck. Oil should cover most of

Negative Cables to Battery

dipstick.

 

Installation

3. If level is low, fill to top of oil filler neck

(See Figure 14). Use proper lube oil to

FUEL

preserve your engine.

Diesel fuel pre-

NOTE: If oil level is too low, oil alert

sents a hazard of

fire. Diesel fuel is flammable.

system will shutdown engine and prevent

• Keep fuel out of children’s reach.

engine from restarting.

Refuel generator in a well-vented area. Do not fill fuel tank in the dark. Do not refuel while engine is running. Unhook all electrical loads and shut off engine before refueling.