Version 1.0 March 1, 2000 Page 35
2.0 Power Section Definition
Note: Power Section is pre-defined at the factory. Power Section
Definition is required if a new board CUR board is put into the drive or
boards are switched between units with different ratings. CUR cards will
exist Regen Rectifiers and Large Common Rectifiers. The smaller
Common Rectifier will not have parameters. Drive should be defaulted
and re-parameterized after Power Section Definition.
P051 = 3
P052 = 2
P070 = xxx
P052 = 0
P51=3 : Export Mode
P52=2: Function select “Initialization”
Input Code for unit (PWE)
(Refer to the following table)
Return to Parameter Menu