8
WARNING: DO NOT RECHARGE FOR MORE THAN
1.NOTE: If unit is fully discharged, it is recommended that the vehicle being used for recharging be left running while the unit is being charged via the
2.Insert one end of the DC/DC charging cord into the
3.Insert the plug at the other end of this power cord (Fig. 5 #4) into the
4.Charge the unit until the green CHARGED indicator is
5.Remove the power cord and store in a safe place.
4.3 Recharging
1.For maximum battery life, we recommend that the INDUSTRIAL 900™ system be kept fully charged at all times. If the battery is allowed to remain in a discharged state, battery life may be shortened.
Note: Recharging battery after each use will prolong battery life; frequent discharges between recharges will reduce battery life. Table I shows the relationship of the frequency of use between recharging and the expected number of discharge/recharge cycles.
TABLE I. - ESTIMATED BATTERY LIFE
AVERAGE NUMBER OF USES | POTENTIAL TOTAL NUMBER |
(JUMPSTART OR DISCHARGES) | OF JUMPSTART OR DISCHARGE CYCLES |
BETWEEN RECHARGES | (LIFETIME OF UNIT BATTERY) |
9
5.1To Use The Industrial 900™ System As A
1.NOTE: Make sure that the unit ‘s safety ON/OFF switch is ALWAYS in the OFF position when using the
2.Lift up the cover of the unit ‘s
3.Insert the
4.Switch on the appliance, as usual.
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 15 AMPS.
Table III shows the estimated
TABLE III. - INDUSTRIAL 900™ AS A 12-VOLT DC POWER SUPPLY
APPLIANCE TYPE | ESTIMATED POWER | ESTIMATED USAGE |
| CONSUMPTION (IN WATTS) | TIME (IN HOURS) |
|
|
|
CELL PHONE | 3 | 35 |
FLUORESCENT LIGHT | 4 | 30 |
RADIO, FAN, DEPTH FINDER | 9 | 21 |
CAMCORDER, VCR, SPOTLIGHT | 15 | 12 |
POWER TOOLS, BILGE PUMP | 24 | 7 |
ELECTRIC COOLER | 48 | 3 |
AIR COMPRESSOR, CAR VACUUM | 80 | 1.5 |
1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000+ 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700+ 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 500+
2.The time required to fully
NOTE:ALL TIMES ARE APPROXIMATE, AND BASED UPON FULLY CHARGED UNIT.
recharge the INDUSTRIAL 900™ system after jumpstarting an engine depends on how
many jumpstarts are performed between recharging sessions. Table II shows the approximate recharging times to be expected.
TABLE II. - ESTIMATED RECHARGING TIMES BASED ON NUMBER OF JUMPSTARTS (OR DISCHARGES) PERFORMED SINCE LAST FULL CHARGING
NUMBER OF | RECHARGING | NUMBER OF | RECHARGING | ||
JUMPSTARTS | TIME (IN MINUTES) | JUMPSTARTS | TIME (IN MINUTES) | ||
| 1 | . . . . . . 8 | 4 | 32 |
|
2 | . . . . . . 16 | 5 | 40 |
| |
3 | . . . . . . 24 | 6 | 48 |
| |
|
|
|
|
|
|
3.Note: Check the battery charge level by depressing the PUSH FOR STATUS switch. The L.E.D. display will show the level of the battery ‘s charge.
5.2To Use The Industrial 900™ System As A
1.IMPORTANT: Before using the unit as a
2.Make sure that the inverter ‘s power switch is in the OFF position before recharging or making any connection to power source or load.
3.Line up the body housing on the Vector™ Power Force 150™ inverter (sold separately for Model VEC021; included with Model VEC021AC) with the mounting walls on the back of the INDUSTRIAL 900™. Slide the inverter into place, from right to left. See Fig. (2) #4.
4.Note the convenient
5.NOTE: Once inverter is properly in place,
6.Remove the inverter‘s adapter cord from its storage compartment, and plug the cigarette
7.Plug the appliance‘s
8.Turn the inverter power switch to ON.
9.Turn the appliance on, and operate as normal.
10.After use, unplug the inverter‘s adapter cord from the front of the unit and replace in the storage compartment.