Vector VEC1026BD Using The Emergency Area Light, Care And Maintenance, Specifications, Warnings

Models: 250 BD050205 VEC1026BD

1 6
Download 6 pages 28.69 Kb
Page 6
Image 6
AC Power Supply Controls and Indicators

VEC1026BD_Manual_050305 5/9/05 2:25 PM Page 6

4.AC Power Ground Fault Circuit Interrupt (GFCI) — A 3-prong outlet for 120 volt AC appliances which shuts down inverter if leakage or ground fault current is detected.

5.Internal protective circuits including:

Overload and over-temperature shutdown (activated if AC output exceeds 250 watts)

AC short-circuit shutdown

Low voltage shutdown

A new cooling technology that more efficiently cools the power transistors and, combined with soft start, dramatically increases reliability and product life

AC Power Supply Controls and Indicators

The Inverter ON/OFF Switch turns the AC power circuitry on and off. The ON/OFF switch can also be used to reset the AC power after shutdown due to overvoltage, overload or over-temperature condition. The AC outlet (covered when not in use) supplies power to AC appliances.

AC Power Supply Operation

1.Turn power switch to ON (the power indicator lights).

2.Plug in appliance and turn the appliance on.

Note: The AC power supply shuts down automatically when the battery voltage level is too low. If the LED flashes, a faulty condition such as an overload, overheating or short circuiting has occurred. Turn the AC Power Supply off and unplug the appliance. Wait a few minutes, then turn power back on.

USING THE EMERGENCY AREA LIGHT

The Area Light is controlled by the ON/OFF slide switch directly above it on the front panel. Make sure the light is turned OFF when the unit is being recharged or stored.

CARE AND MAINTENANCE

AC Power Supply Operation CAUTION

If the cord, wires, or cables become damaged, do not attempt to use. Return the entire unit to Vector Manufacturing for service and repair.

Replacement Parts

For replacement parts (bulbs, batteries, fuses, etc.), contact Customer Service toll-free at (800) 618-5178.

Battery Replacement/Disposal

It is recommended that the unit be returned to Customer Service for battery replacement. Contact toll-free (800) 618-5178.

This unit contains a maintenance-free, non-spillable, sealed lead- acid battery. This battery is fully recyclable and should be accepted at any location that accepts common automotive starter batteries. Examples of places that accept these batteries are: county or municipal recycling drop-off centers, scrap metal dealers and retailers who sell automotive replacement lead acid starter batteries.

USING THE EMERGENCY AREA LIGHT WARNINGS

Do not dispose of the battery in fire, as this may result in an explosion.

Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).

Do not expose battery to fire or intense heat, as it may explode.

Fuse Replacement (DC Accessory Adapter)

1.Remove plug from accessory receptacle. Remove the gold cap by turning counterclockwise and lifting off.

2.Remove center pin and spring. Remove fuse.

3.Replace fuse with same type and size fuse.

4.Replace center pin and spring inside plug.

5.Replace gold cap by turning clockwise.

SPECIFICATIONS

Jump-Start Clamps:

Heavy-duty copper

Jumper Cables:

#6AWG welding cables

Instant Starting Amps:

300 amps

AC Power Output:

250 watts AC

DC Power Output:

12 volts DC

Battery High-density

 

AGM:

12 volt, 9 amp hour, sealed lead-acid

Accessory Outlet

 

Protection:

Automatic overload protection

6

7

Page 6
Image 6
Vector VEC1026BD Using The Emergency Area Light, Care And Maintenance, Specifications, AC Power Supply Operation, Warnings