OPERATING THE LED EMERGENCY LIGHT

VEC130B_Manual EN_030906 5/25/06 1:52 PM Page 6

Extend the Telescoping Antenna and adjust for best reception.

Adjust the volume using the Volume Control Knob on the side of the unit.

Press the Alert Pushbutton to turn the Alert feature ON (the Alert LED will light) and press the ALARM/LOCK Pushbutton to set it in LOCK position (the Alarm Lock LED will light) for Alert standby mode. Note that the speaker is muted while Radio monitors for a hazard alert.

Notes: While in the ALERT position, the hazard alarm will sound briefly when a hazard alert is received. While in the LOCK position, the alarm sounds continuously when the hazard alert is received.

While in either ALERT or LOCK mode, the AM/FM and WEATHER radio stations will function.

For the LOCK function to be available, ALERT must be engaged.

OPERATING THE LED EMERGENCY LIGHT

The LED Emergency Light on the front of the unit is controlled by the ON/OFF Pushbutton on the top of the unit (see the “Control and Function Guide” on page 2).

CELL PHONE CHARGING

Plug the appropriate tip from the Cell Phone Charging Adapter Set into the cell phone and attach the other end to the supplied cell phone extension cord. This plugs into the Cell Phone Charging Port (see the “Control and Function Guide” on page 2). None of the unit’s features need be on for cell phone charging to take place. The unit does need to be powered (“C” batteries, 120 volt AC, 12 volt DC or the Dynamo Hand-Crank).

CELL PHONE CHARGING CAUTIONS

Supplied cell phone charging tips may not work with all cell phones.

Using the wrong tip may damage your device. Manufacturer is not responsible for damage caused in this manner.

Verify tip compatibility with your cell phone manufacturer or consult your cell phone user manual before using this unit's cell phone charging feature.

CARE AND MAINTENANCE

Cleaning

Over time, dust or fingerprints may accummulate on the TV screen or LED Emergency Light. If necessary, clean with a soft, clean, oil-free cloth moistened with household window cleaner. Do not use alcohol based cleaners on plastic surfaces. This will eventually cause surface clouding.

Replacement Parts

Check unit periodically and discontinue use if parts or accessories are found to be damaged or defective. To replace worn or defective parts, contact Vector Customer Service toll-free at (866) 584-5504.

Fuse Replacement

1.Using a screwdriver, open the fuse cover on the back of the unit (see the “Control and Function Guide” on page 2) and remove the defective fuse.

2.Insert a replacement 2 amp standard buss type fuse into the fuse socket.

3.Close the fuse cover.

12 Volt DC Adapter Plug Fuse Replacement

The fuse in the DC plug protects the charging circuit of the 12 Volt DC Adapter. If AC powering/recharging works, but DC powering/recharging does not, then the fuse may be opened (blown).

To replace the fuse:

1.Unscrew the end cap of the DC plug (counterclockwise).

2.Remove spring center contact and fuse.

3.Check fuse with a continuity checker.

4.If blown, locate replacement fuse with same type and rating.

5.Replace the fuse, spring, contact and end cap.

6.Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.

7.Test for proper operation of the 12 Volt DC Adapter.

Battery Replacement/Disposal

Battery Replacement

The built-in rechargeable battery should last the life of the unit. In the event it needs replacing, it is recommended that the unit be returned to manufacturer. Contact Vector Customer Service toll-free, at (866) 584-5504.

Battery Disposal

This unit contains an Ni-MH battery and should be disposed of properly. For more information on recycling batteries, call toll free

(800) 822-8837.

CARE AND MAINTENANCE WARNING

Do not expose batteries to intense heat or dispose of them in fire. This may result in an explosion.

Replacement Parts CAUTION

THIS UNIT USES A 2 AMP FUSE. FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE THE FUSE ONLY WITH ONE OF THE SAME TYPE AND RATING.