VEC157CFL_Manual_013205 5/2/05 6:50 PM Page 8
CAUTION
•To reduce the risk of electric shock only replace bulb with 75 watt 12 volt H3 bulb only.
Figures 2A & 2B
HAIRPIN RETAINING
WIRES
PHILLIPS
HEAD
SCREWS
BULB
REFLECTOR
PERIODIC MAINTENANCE
All batteries lose charge with time, especially when they are warm. AC recharge is recommended every two months, when not in frequent use. Use the AC recharger and charge for the recommended time. If the unit gets dirty, gently clean the outer surfaces of the spotlight unit with a soft cloth moistened with a mild solution of water and detergent. Periodically inspect the condition of recharge adapters, connectors, and wires. Replace any components that may have become worn or broken.
PARTS REPLACEMENT
One part is user replaceable. The quartz halogen bulb is proprietary and is available through Vector. A substitute 12 volt H3 75 watt bulb may be used in place of a existing bulb. These can be purchased from popular automotive parts suppliers nationwide. Contact Technical Support for replacement parts and any additional information you may need. They may be reached at (954)
BATTERY REPLACEMENT/DISPOSAL
Battery Replacement
Battery should last the service life of the unit. Contact Technical Support at (954)
Safe Battery Disposal
Contains a
WARNINGS
•Do not dispose of the battery in fire as this may result in an explosion.
•Before disposing of the battery, protect exposed terminals with
•Do not expose battery to fire or intense heat as it may explode.
•For more information on recycling this battery, call
DC PLUG FUSE REPLACEMENT
The fuse in the DC plug protects the charging circuit of the DC recharge adapter. If the AC recharger operates but the DC charging adapter does not, then the fuse may be opened.
To replace the fuse:
1.Unscrew the end cap of the DC plug (counterclockwise).
2.Remove spring center contact and fuse.
3.Check fuse with a continuity checker.
4.If blown, locate replacement fuse with same type and rating.
5.Replace the fuse, spring, contact and end cap.
6.Screw end cap clockwise until it is finger tight – DO NOT
7.Check for proper operation of DC charger adapter.
TROUBLESHOOTING
•No red charge light
If red LED does not turn on when charging do the following:
A)Check for bad connection to the spotlight recharge port
B)Check for bad connection to AC or DC adapters
C)Confirm there is a functioning AC or DC current
Operating Issues
1.When charging spotlight will not operate. Area light will turn on when pressed while charging. Be sure spotlight charge port is disconnected before main beam usage.
2.If trigger can’t be fully depressed, check to see if trigger lock is locked. If it is, release the trigger lock.
3.If unit does not operate battery may be completely discharged. Charge unit using AC adapter following the directions in the manual.
4.If you suspect a bulb is blown check bulb filament. If filament is coiled and unbroken, the bulb is not blown. If filament is blown, replace bulb.
8 | 9 |