41TDM Menutree

Main Menu Network Configuration

 

Mode: DDS-I, TXP-I, TXP-II, DDS-II

 

 

 

Rate: 56 K and 56 K

 

 

 

 

Timing: Network and Internal

 

 

 

Circuit Assurance: Off and On

 

 

 

Antistreaming Timer: - --, 10 seconds, 30 seconds, 60 seconds

 

 

Alarm Thresholds: FDL, OOS, OOF, LOS, ART

 

 

 

 

 

 

 

 

 

DTE Configuration Mode: TDM and STD

Port A Format: Sync and Async

Port B Rate: 2.4, 4.8, 9.6, 19.2, 31.2, 38.4, 52, 56, 57.6, 60, 64 kbps

Interface: RS-232, V.35, EIA-530

DSR: Force T and Test>Off

DCD: Force T, Far RTS, Idle>Off

RTS: Force On and Normal

RTS/CTS Delay: Normal and Long

DTR Alarm: Dis and En

V54 Loop: Dis and En

LLDetect: Dis and En RL Detect: Dis and En

SNMP Configuration

Unit IP Addr*

 

 

 

 

 

 

 

 

 

 

 

 

Router IP Addr*

 

 

Subnet Mask*

 

 

 

 

Fltr 1– 6 Addr*

 

 

 

SETs: Enable and Disable

* An underscore appears

 

Read Community*

 

under the character to

 

Write Community*

 

be entered or modified.

 

Sys Contact*

 

 

 

Sys Name*

 

 

 

Sys Location*

 

 

 

Reset LAN: No and Yes

 

 

Diagnostics

 

Loop Mode: Uni and Bi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BERT Function

 

BERT: On and Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset: No and Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SynLos (display only)

 

 

 

 

 

 

 

 

 

 

 

 

ErrSec (display only)

 

 

 

 

 

 

 

 

 

 

 

 

BitErr (display only)

 

 

 

 

 

 

 

 

 

 

 

 

Time: HH:MM:SS (display only)

 

 

 

 

 

 

 

 

 

 

 

Sync

 

No Test (display only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In Sync (display only)

 

 

 

 

Local Loop: Off and On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Far V.54 Loop: Off and On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V.54 Loop: Off and On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTE-A Loop: Off and On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTE-B Loop Off and On

 

 

 

 

 

 

 

 

 

Utilities

 

Save Configuration: No and Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPV: 1.2 K, 2.4 K, 9.6 K, 19.2 K

 

 

 

 

 

 

 

 

 

 

 

SLIP: 1.2 K, 2.4 K, 9.6 K, 19.2 K

 

 

 

 

 

 

 

 

 

 

 

 

IP Port: SLIP

 

 

 

 

 

 

 

 

 

 

 

 

 

Date: MM/DD/YY

 

 

 

 

 

 

 

 

 

 

 

Time: HH:MM:SS

 

 

 

 

 

 

 

 

 

 

 

 

 

Contrast: 0 – 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Displays

 

Status: FDL, LOS, OOS, OOF, Idle, Test

 

 

 

 

 

A:

 

RS, CS, CD, TR, SR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B:

 

 

 

 

 

 

 

 

 

 

 

Configuration

EXIT

Press this button on the last char- acter to enter the value and return to the previous screen.

SCROLL

Press this button to increment the characters (a – z, A – Z, 0 – 9, spe- cial characters).

SELECT

Press this button to accept the cur- rent value and move the cursor right.

Indicators

TDM

This amber indicator is On when the unit is configured for TDM (Time Division Multiplexer) mode.

TEST

This amber indicator is On when the unit transmits loop code, un- loop code, the 511 BERT pattern, or when the unit is placed in a loop mode such as line, data, V.54, etc.

ALARM

This red indicator is On when the unit is in an active alarm condition.

POWER

This green indicator is On when power is applied to the unit.

127 Jetplex Circle Madison, Alabama 35758

(800) 837- 4546

www.verilink.com

FAX-On-Demand (800) 957-5465

Technical Assistance Center (800) 285- 2755

Page 2
Image 2
Verilux specifications 41TDM Menutree, Configuration, Indicators