Sanitizing Wand Operation continued
For example, if you’ve been using the Wand for 3 minutes and 20 seconds,
the Wand will show “20.” Press the button and the display will briefl y show “03”
before continuing the by-the-second count-up to minute “04.”
Step by step:
1. To turn the Wand on, press the blue button until the Wand beeps – about
two seconds.
2. Lift your fi nger off the button. The Wand will turn on. The fl uorescent bulb
may take another second or two to light.
3. The display window will show the count-up timer.
4. Begin sanitizing by holding the Wand as close as possible and no more than
one-half inch above the surface and moving Wand slowly side to side in a
12” (1 foot) area. The energy required to kill microorganisms is a product of
the light’s intensity and exposure time. The closer the Wand is to an object,
the more intense the energy. See Guidelines for Use (page 12) for more
specifi c information.
5. Move the Wand to next 12” (1 foot) area and continue sanitizing.
6. Repeat until you have completely sanitized your desired surface area.
7. When you have fi nished, press the blue button for three seconds. The Wand
will turn off.
NOTE: Be sure the Wand is facing downward, directly over your desired
sanitizing area. A safety switch will automatically turn off the UV-C light if the
Wand is tilted upward from the horizontal position. (The counter will not stop
during this temporary bulb safety shut-off.)
When the battery charge is low, the Wand will begin to beep and the red
indicator light will fl ash, indicating that the battery needs to be charged.
Using the Wand in Charging Mode
The Wand can be used in charging mode simply by connecting the power
adapter to the Wand and following the Operation instructions shown above.