WALL FRAMING DIMENSIONS
Vent Opening for
Combustible Wall
9³⁄₈"
(240 mm)
9³⁄₈"
(240 mm)
Fireplace Hearth | Framing Detail |
Opening for Non-combustible Wall
Rnd.
7¹⁄₂" Dia.
(190 mm)
MINIMUM FRAMING DIMENSIONS
2 x 4's
2 x 4
2 x 4
Header
|
|
|
|
|
|
|
| ||
2 x 4 | (753mm) |
|
| ||||||
| |||||||||
| |||||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| (368mm) | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| ||||||||
|
| (851mm) |
|
|
| (851mm) |
FLUE SYSTEM
7” Coaxial Direct Vent System
SPECIFICATIONS:
•7” O.D.
•4” I.D.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL
a) | Vertical Side Wall Applications | 1” to All Sides |
b) | Vertical thru the Roof Applications | 1” to All Sides |
MINIMUM COMBUSTIBLE WALL/FLOOR OPENINGS
a)9 3/8” W x 9 3/8” H for Vertical Side Wall/Vertical Applications
MAXIMUM INSTALLATION LENGTHS
a)Vertical Side Wall Applications
36” (914 mm) Horizontal Vent Length with 90°
elbow installed directly on top of the unit 20ʼ (6 m) Horizontal Vent Length with 7.5ʼ (2.29 m) vertical rise
*Refer to manual for alternative venting distance
VERTICAL THRU THE ROOF APPLICATIONS
•8ʼ (2.4 m) Minimum Vertical Rise
•40ʼ (12 m) Maximum Vertical Rise
•2 sets of 45° Elbows can be used in Vertical rise with 8ʼ maximum distance between elbows
•Two 90° elbows maximum for 10ʼ (3 m) Horizontal can be installed in Vertical Applications
*Maximum angular variation for Vertical Sidewall/Vertical Application in system is total of 270°
*Refer to installation manual for all venting restrictions with elbow use
TERMINATION CLEARANCES MINIMUM a) Horizontal
12” (305 mm) above Grade Level 18” (458 mm) to Ventilated Soffit 12” (305 mm) to Unventilated Soffit
12” (305 mm) under veranda, porch, deck or balcony
b) Vertical
24” (610 mm) Above a Roof Surface and any other obstruction within a horizontal distance
of 18” (458 mm)
*Refer to installation manual for more termination restrictions
PRODUCT LISTING
33LDVT ANSI Z21.88 - 2005/CSA 2.33 2005 Vented Gas Fireplace Heaters
This gas appliance should be installed by qualified installers in accordance with local building codes and the current National Fuel Gas code ANSI Z223.1 or CSA B 149.1 Installation code for Gas Burning Appliance and Equipment.