Vermont Casting 410 Madison 1655 Series Clearance Chart, R 8”, X 8”, AA 12”, BB 15”, CC 16”

Models: 410

1 28
Download 28 pages 17.81 Kb
Page 12
Image 12
Madison 1655 Series Clearance Chart

Madison Woodburning Stove

Madison 1655 Series Clearance Chart

Use the chart below together with the diagrams on the next page to determine the minimum clearance required for your particular installation. In any case, it is always advisable to locate the stove as far away from walls as pos- sible in order to take full advantage of the radiant properties of cast iron.

Stove clearances are measured between the cast iron Top Plate of the stove and the combustible surface. Note that the cast iron back on the Madison protrudes 5” (127mm) out from the stovetop, and will therefore be closer to the wall than the top of the stove.

Chimney Connector clearances are measured between the connector surface and the combustible surface. For Douible-wall Chimney Connector, use the manufacturer’s listed clearance specification.

Use NFPA 211 default clearance or manufacturer’s installation specifications for those configurations not tested.

UNPROTECTED SURFACES

PROTECTED SURFACES

 

 

 

 

Parallel Installation

Corner

Parallel Installation

Corner

 

 

 

 

STOVE CLEARANCE

 

Installation

Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

Rear

Corner

Side

Rear

Corner

 

 

 

 

 

 

 

 

 

 

Top exit, no heat shields

 

A 21”

B 24”

C 21”

D 12”

E 14”

F 10”

 

 

 

 

 

 

(533mm)

(610mm)

(533mm)

(305mm)

(356mm)

(250mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, heat shields on stove,

 

G 21”

H 24”

I 21”

J 12”

K 14”

L 10”

 

 

 

 

no shields on single wall

 

 

 

 

 

 

(533mm)

(610mm)

(533mm)

(305mm)

(356mm)

(250mm)

 

 

 

 

connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, heat shield on stove,

 

M 21”

N 22”

O 18”

P 12”

Q 14”

R 8”

 

 

 

 

heat shield on single wall

 

 

 

 

 

 

(533mm)

(559mm)

(457mm)

(305mm)

(356mm)

(203mm)

 

 

 

 

connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit, heat shield on stove,

 

S 16”

T 12”

U 18”

V 12”

W 11”

X 8”

 

 

 

 

double wall chimney connector

 

(406mm)

(305mm)

(457mm)

(305mm)

(279mm)

(203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear exit, no heat shields

 

Y 18”

Z 20”

N/A

AA 12”

BB 15”

N/A

 

 

 

 

 

(457mm)

(508mm)

(305mm)

(381mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear exit, heat shields

 

CC 16”

DD 18”

N/A

EE 12”

FF 12”

N/A

 

 

 

 

 

(406mm)

(457mm)

(305mm)

(305mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHIMNEY CONNECTOR

 

UNPROTECTED SURFACE / Vertical

PROTECTED SURFACE / Vertical

 

 

 

 

CLEARANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Without Connector Heat Shields

 

 

19” (483mm)

 

 

13” (330mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With Connector Heat Shields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNPROTECTED SURFACE / Horizontal

PROTECTED SURFACE / Horizontal

 

 

 

 

Single-wall Connector

 

 

23” (584mm)

 

 

23” (584mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT CLEARANCE

 

 

 

ALL INSTALLATIONS

 

 

 

 

 

 

 

 

TO COMBUSTIBLES*

 

 

 

48" (1220mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*A distance of 48" must be maintained between the stove and moveable combustible items such as drying clothes, furniture, firewood, etc.