Inspire Electric Fireplace

Installation Instructions

General

1.Read all instructions before using this appliance.

2.This appliance is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this appliance. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains away at least 3’ (914 mm) from the front of this appliance.

3.CAUTION: Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating unattended.

4.If possible, always unplug this appliance when not in use.

5.Do not operate any heater with a damaged cord or plug or after the appliance malfunctions, has been dropped or damaged in any manner.

6.Any repairs to this appliance should be carried out by a qualified service person.

7.Under no circumstances should this appliance be modi- fied. Parts having to be removed for servicing must be replaced prior to operating this fireplace again.

8.Do not use outdoors.

9.This heater is not intended for use in bathrooms, laun- dry areas and similar indoor locations. Never locate this appliance where it may fall into a bathtub or other water container.

10.Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic areas and where it will not be tripped over.

11.To disconnect this appliance, turn controls to the off posi- tion, then remove plug from outlet.

12.Connect to properly grounded outlets only.

13.This appliance, when installed must be electrically grounded in accordance with local codes, with the current CSA C22.1 Canadian Electrical codes or for US installa- tions, follow local codes and the National Electric Code, ANSI/NFPA No. 70.

14.Do not insert or allow foreign objects to enter any venti- lation or exhaust opening as this may cause an electric shock, fire or damage the appliance.

15.To prevent possible fire, do not block air intakes or ex- haust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.

16.This appliance has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored. This appliance should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung on or near it.

17.Use this appliance only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.

18.Avoid the use of an extension cord because of the risk of overheating the cord and the risk of fire. Extension cords are for temporary use only. If an extension cord must be used, it must be UL/CSA certified, rated at 15A (1875W), 125 V maximum with 14 AWG minimum and constructed of two current carrying conductors with ground. A heavy duty extension cord with the shortest length possible for this connection is recommended and must not be longer than 50 ft. (15.2 m). Do not coil or cover the extension cord.

Locating Your Fireplace

When choosing a location for your new fireplace, en- sure the general instructions are followed. Also, for best effect, install the fireplace out of direct sunlight.

Clearance to Combustibles

Sides (including trim assembly)

........... 0” (0 mm)

Bottom

9⁷⁄₈” (250 mm)

Top

3’ (914 mm)

Unit: EFHI4S0

 

SAVE THESE

INSTRUCTIONS

10009472

3

Page 3
Image 3
Vermont Casting ICVCTK01, ICVCTK02 Installation Instructions, General, Locating Your Fireplace, Clearance to Combustibles

ICVCTK01, ICVCTK02 specifications

Vermont Castings offers a range of high-performance gas fireplaces, and two notable models in their lineup are the ICVCTK02 and ICVCTK01. These models stand out for their blend of classic design, advanced technology, and powerful heating capabilities.

The ICVCTK02 and ICVCTK01 fireplace inserts share many features that make them popular choices among homeowners looking to enhance their living spaces with warmth and ambiance. One of the most prominent characteristics of these models is their elegant cast iron construction, which not only provides a timeless aesthetic but also contributes to efficient heat retention and distribution. The durable cast iron body helps maintain consistent temperatures, allowing for even heating throughout the room.

Both models are equipped with Vermont Castings' innovative burner technology, designed to provide a clean and efficient burn. This ensures that these fireplaces offer a higher heat output with lower emissions, making them an environmentally friendly choice. The advanced burner system also provides the option for both natural gas and propane fuel sources, catering to the preferences and availability of different households.

An important feature of the ICVCTK02 and ICVCTK01 is their impressive BTU output. These models are capable of producing a substantial amount of heat, making them well-suited for rooms of various sizes. The controlled heat output allows users to customize their heating experience, ensuring comfort during colder months.

Furthermore, the ICVCTK02 comes with the additional advantage of a multi-function remote control, allowing homeowners to adjust the flame height, control the blower speed, and set timers without having to leave their seats. The ICVCTK01, while slightly more basic in its controls, still offers easy access to user-friendly features that enhance the overall experience.

Both fireplace inserts also emphasize usability and safety. They feature a large viewing window that provides a great view of the beautiful flames, while the glass door keeps the fire contained and safe. Additionally, safety features include a heat-resistant glass and ventilation systems designed to reduce the risk of overheating.

In summary, the Vermont Castings ICVCTK02 and ICVCTK01 fireplace inserts combine elegance, efficiency, and modern technology. With their stunning cast iron design, advanced burner performance, and user-friendly features, these fireplaces are an excellent investment for creating a cozy and inviting atmosphere in any home.