Natural Gas Grills - Connecting to Natural Gas
(for specially equipped natural gas grills only)
DANGER: EXPLOSIVE AND FLAMMABLE! If the appliance is for connection to natural gas, the gas connections should be made by a qualified installer or a licensed plumber. The
The
WARNING: Do not use liquid propane (L.P.) gas in an appliance designed for natural gas. Use only natural gas in an appliance designed for natural gas.
INSTALLATION FOR NATURAL GAS
The maximum inlet supply pressure is 11.0" w.c. for propane gas and 7.0" w.c. for natural gas.
The specified supply pressure is 11.0" w.c. for propane gas and 7.0" wc. for natural gas.
The piping system should be installed by a qualified service technician in accordance with the National Fuel Gas Code (NFPA 54/ANSI
Z223.1) in the U.S.A., including:
1.The appliance and its individual
2.The appliance must be isolated from the
A
It is important to observe the safety guidelines for choosing a safe location. The gas supply must be shut off prior to installation of the quick connector socket. Use only a matching factory authorized
Dust Cap
Connector Socket | Gas Flow |
One example of an Individual
Prior to inserting, turn on gas supply and test all connections with an
21