Gas Hookup

NATURAL GAS SUPPLY CONNECTION

TO CONNECT:

1.Push back the Sleeve on the Socket as shown below (see Fig. 6a).

2.Insert Plug and release the Sleeve (see Fig. 6b).

3.Push the Plug until Sleeve snaps forward to lock the Plug in the Socket.

WARNING: Always conduct the following safety tests before lighting the Grill, to prevent a possible fire or explosion (see leak test below).

TO DISCONNECT:

1. Push Sleeve back and pull the Plug out.

Retract Sleeve

Fig. 6a

Release Sleeve

 

Release Sleeve

Fig. 6b

 

TESTING FOR GAS LEAKS (for LP and Natural Gas)

Before attempting to operate this Grill:

1.Always confirm that all burner control knobs are in the OFF position.

2.Always connect the gas supply hose first and then open the gas shutoff valve.

3.Always use a brush or spray bottle to apply a 50/50 solution of liquid soap and water to all connection points (see Fig. 5) to test for gas leaks. Never use a match or open flame for that purpose.

4.Always look for bubbles to appear, as the appearance of bubbles will indicate a gas leak. Always turn off the gas immediately and tighten the connection, if you find that a leak exists.

5.Always repeat this procedure until no further gas leaks are found to exist, before lighting the Grill.

6.Never attempt to light this Grill, however, if a leak cannot be stopped. Always call your gas supplier promptly to obtain assistance.

WARNINGS:

Always consult the Rating Label on the back of the Grill to confirm that it has already been configured to burn Natural Gas.

All gas supply plumbing should be performed only by a qualified service agency. In the U.S., the supply connection must be made in accordance with local code or, in the absence of local codes, with the national fuel gas codes, ANSI Z223.1/NFPA54. In Canada, the supply connection shall be carried out in accordance with the provincial authorities having jurisdiction and in accordance with the requirements of the CAN/ CGA 1-B149.1 installation code. A shutoff value must be installed between the gas grill and the main supply. For natural gas, use a 3/8” or 1/2” natural gas supply line capable of an a input of up to 100,000 BTUs (depending on the model).

Always disconnect the Grill and close its individual manual shutoff valve, when conducting pressure tests of the gas supply piping system at pressures which exceed 1/2 psi (3.5 kPa).

Always isolate the Grill from the gas supply piping system by closing its individual manual shutoff valve.

Page 5

Page 10
Image 10
Vermont Casting VCS5027 user manual Natural GAS Supply Connection To Connect, To Disconnect

VCS5027 specifications

The Vermont Casting VCS5027 is a highly regarded wood-burning stove known for its impressive heating capabilities, aesthetic appeal, and innovative technology. Designed to provide warmth and comfort to homes, this model combines traditional craftsmanship with modern efficiency.

One of the primary features of the VCS5027 is its high-efficiency heating system. With an EPA-certified design, it adheres to strict emissions standards, ensuring that it burns cleaner and more efficiently than many traditional wood stoves. This model can produce an impressive amount of heat, making it suitable for heating larger spaces or entire homes, while also reducing fuel consumption.

The VCS5027 is built with heavy-duty cast iron construction, which not only enhances durability but also provides excellent heat retention. This material allows the stove to distribute warmth evenly and maintain its temperature for extended periods, even after the fire has diminished. The cast iron body, along with the stainless steel components, gives the stove a timeless look that complements various interior styles.

Another standout feature of the VCS5027 is its air wash system. This innovative technology helps keep the glass door clean by directing air across the surface, reducing soot buildup and allowing for a clear view of the fire within. The large ceramic glass window offers a panoramic view of the flames, enhancing the overall ambiance of any room.

Moreover, the Vermont Casting VCS5027 incorporates a secondary combustion system, which maximizes heat output while minimizing smoke emissions. This system enhances the efficiency of the stove by igniting gases and particulates produced during the burning process, resulting in a cleaner burn and reduced environmental impact.

Ease of use is another essential characteristic of the VCS5027. It is designed with user-friendly controls, allowing users to adjust the airflow and heat output with minimal effort. Additionally, the stove features a straightforward loading design, making it easy to add wood as necessary.

In summary, the Vermont Casting VCS5027 wood-burning stove stands out for its combination of efficiency, durability, and aesthetic appeal. With its high-efficiency heating, sturdy cast iron construction, air wash technology, and user-friendly design, it offers both functionality and a classic look. Whether for a cozy cabin or a family home, the VCS5027 promises to deliver warmth and charm for years to come.