OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS

Remove the gratings, the burner covers and the knobs;

Using a wrench substitute the nozzle injectors “J” (fig. 5.6) with those most suitable for the kind of gas for which it is to be used.

The burner are conceived in such a way so as not to require the regulation of the primary air.

J

Fig. 5.6

INJECTORS TABLE

 

NOMINAL

REDUCED

LP/PROPANE

NATURAL GAS

 

POWER

POWER

11” W.C.P.

4” W.C.P.

BURNERS

BTU/hr

BTU/hr

Ø injector

By-pass

Ø injector

By-pass

[1/100 mm]

[1/100 mm]

[1/100 mm]

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

Semi-rapid (SR)

6000

1500

72

34 (*)

118

adjustable

Rapid (R)

10000

2000

94

44 (*)

155

adjustable

(*) 34: brown coloured 44: green coloured

REGULATING THE BURNER MINIMUM SETTING

When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when passing suddenly from maximum to minimum flame.

To regulate the flame follow the instructions below:

Light the burner

Set the gas valve to minimum

On gas valves provided with adjustment screw in the centre of the shaft (fig. 5.7):

Using a screwdriver with max. diameter 3 mm, turn the screw inside the tap until the correct setting is obtained.

For LP/PROPANE gas, tighten the adjustment screw completely.

After regulation repeat the operations indicated in paragraph “2. Pressure regulator” at page 12.

If the cooktop has been disconnected and then connected again to the gas supply line repeat the operations indicated in paragraph “5. Leak Testing” at page 16.