Victory Refrigeration VBB-72 TemperatureControl, TechnicalService& ReplacementParts, Condenser

Models: VBB-60 VBB-48 VDD48 VBB-72 VDD-60 VDD-72

1 6
Download 6 pages 58.83 Kb
Page 2
Image 2
TemperatureControl

5 . Rinsewith clear water and dry with soft absorbent towel.

6 . Reinstallshelves .

7 . Restorepowerto refrigerationsystem by placingplug

i n i ^ r o a p n i 2 n l a

, , , ! v ' v v v P ! u v ' v .

8 . Returnbeverageswhen cooler has reachedworking temperature .

IMPORTANT!CONDENSERMAINTENANCE To keepyourcoolerrunningefficientlyand trouble free,cleanthe condensetcoil at leastonceevery three monthsor moreoften.

1-. Removebeveragesandclosedoors .Pullcoolerforward and removepowercord from receptacle.

2 . For condensercoil access, removetwo screws from bottomof front grill .Use both handsto carefullypull grillup and awayfrom cabinet .

3 . To properlyclean the condensercoil, compressor - motorand relatedparts:

TemperatureControl

Coolertemperaturecontrolsare

^ i i , ' a + a A

^ f

+ h ^

f a a t 6 7 1 7

h o f n r a

d u l u J L U U

d L

L l l u

l d u L u r ) i

u u r v r L .

shippingto maintainan average temperatureof 36'F(2 . 2"C) and should not need adlustment . Controlis locatedbehind vented front panel .

K

ry "'.

r:l!-b"

Evaporator Fan Switch

a)Use a vacuum cleaner with proper brush attachments.

b)Use a soft bristledbrush in a "rollingmotion"to get dirt and grimeon the brush .Do not push dirt and Crime into the coil, and do not flatten coil fins.

c)lf yourcondenserbecomesplugged,calla service companyfor a professionalcleaning .

4 . Aftercleaning,reassemblecoolerand properlyrestore power.

5 . Return cold beverageswhen cooler has reached workingtemperature .

Condenser

"NoTE:DlsconnectPowerSupply BetoreAttemptlnganyServicel" Temporalurocontrolshouldbsturnodt0 "0FF"posltlonbeloreunplugglngcooler. Besur0t0returnlem0EratuISc0nlr0l

looriginalsetlingaltertec0nneclingpower.

TechnicalService& ReplacementParts

VictoryRefrigerationstrivesto provideexcellentcustomer servicealongwith qualityequipment .To help us better assist you, a serialnumberand/or model numbermust be providedwhencontactingthe technicalserviceor parts department .The data plate is locatedinsidethe cooler on the uooerleftwall .Allserialnumbersare recordedand kept indefinitely .

Referto the guide on the back page of this document priorto callingfor technicalassistance .

Technicalinformationand replacementpartssupportcan also be obtained via website. Just go to www.victory- refrig . comand clickon the customerservicelink .

CommonReplacementParts

-

 

(1) G31580O27DoorGasket 48" Door

-

 

(2) G31580026DoorGasket 60" Door

-72"

Door

(3) G31580025DoorGasket

(4)GIL237O0OFanBlade (5\ GI6477OO0FanMotor

(6)G18960000Timer

(7)G19230000ColdControl

(8)G18930000FluorescentLamp

(9)G16915000Switch

(10)G19166000HousingBallast

(11)GNUT6B90PUN301CondenserFanMotor