13 ViewSonic PJ250
STATUS Indicator Light

Note:

Should the projector not project properly, see the Troubleshooting section of the User Guide.

STATUS
Indicator POWER
Indicator Problem
Flashes red
(0.5 s lit /0.5 s
off)
Lit red The temperature has become abnormally high.
The thermal protector is activated. if the room temperature i s high,
move the projector to a cool location. If the internal temperature of the
projector is high, check the ventilation holes of the c ooling fan and
clean them if they are obstructed.
When the thermal protector is activated, the power is switched off and
even if the power is soon switched back on, the power might not actu-
ally be supplied to the projector. Should this happen, wait one minute
and then switch the power on again.
Flashes red
(1 s lit / 1 s off)
When the lamp
burns out during
operation: Flashes
amber for 90 sec-
onds and then stays
lit
When the lamp
does not turn on:
Lit amber
The lamp will not turn on
Wait one minute or longer while the lamp lighting voltage irregul arity
detection protector is activated and switch the power on agai n. If the
problem still persists, unplug the power cable and contact ViewSoni c.
Flashes red
(0.5 s lit /0.5 s
off)
Lit amber The fan has stopped.
Unplug the power cable and contact ViewSonic.
Flashes red
(1 s lit / 1 s off)
Lit red The lamp cover is open.
The lamp cover is not attached properly.
Attach it properly.
Lit red Lit amber after 90
seconds of flash-
ing in amber
The lamp will not turn on.
The lamp has reached end of life. Contact your reseller or ViewSon ic
for a replacement lamp.
STATUS indicator POWER indicator