ALIGNMENT AND TEST PROCEDURES
7-19 March 1999
Part No. 001-2009-600
2. Inject a 1.2 kHz tone from a balanced 600 ohm
source, at the level determined by the type of line
used, into TXS+ and TXS- of J2 located on the back
of the Repeater (see Figure 7-14).
Leased Line/Direct Connect (default)
-12 dBm (194 mV RMS)
Microwave/T1 (optional)
-28 dBm (31 mV RMS)
3. Adjust R242 on the MAC to obtain -10 dBm (245
mV RMS) measured at J100/J103.
Figure 7-13 S100/S101 SWITCH SETTINGS
Figure 7-14 J2 TERMINAL BLOCK (SECOND-
ARY)
FSK Data Level Adjustment To Repeater
Data over Voice (2-Wire) Default Setting.
1. Set MAC S100, all Sections OFF; S101 Sections 2,
3, 4 OFF; 1 ON (see Figure 7-15).
2. Inject a 1.2 kHz tone from a balanced 600 ohm
source, at the level determined by the type of line
used, into TXA+ and TXA- of J2 located on the
back of the Repeater (see Figure 7-18).
Leased Line/Direct Connect (default)
-22 dBm (62 mV RMS)
Microwave/T1 (optional)
-38 dBm (10 mV RMS)
3. Adjust R242 on the MAC to obtain -10 dBm
(245 mV RMS) measured at J100/J103.
Figure 7-15 SWITCH SETTINGS
Figure 7-16 J2 TERMINAL BLOCK
ON
21
876543
ON
21
43
RXS- (GND)
RXS-
RXS+ (AUDIO)
RXS+ (FSK)
RXS- (GND)
TXS-
TXS+ (AUDIO)
TXS+ (FSK)
S100
S101
FSK
TXS+
2
1
33
34
J2
TXS+
TXS-
RXS-
RXS+
ON
21
876543
ON
21
43
RXS- (GND)
RXS-
RXS+ (AUDIO)
RXS+ (FSK)
RXS- (GND)
TXS-
TXS+ (AUDIO)
TXS+ (FSK)
S100
S101
FSK
TXS+
2
1
33
34
RXA+
RXA-
J2
TXA+
TXA-