Viking dimensions Model DIV1200 Ventilator Kit, Ventilator Kit Installation, Blower Dimensions

Models: DIV1200

1 2
Download 2 pages 50.61 Kb
Page 1
Image 1
Model DIV1200 Ventilator Kit

Model DIV1200 Ventilator Kit

WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:Blower DimensionsVENTILATOR KITManual backgroundManual backgroundManual background

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer or your distributor.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means can- not be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, in- cluding fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Do not use this unit with any solid-state speed control device.

8.To reduce the risk of fire, use only steel ductwork.

9.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.

Never leave surface units unattended at high settings. Boilovers cause

 

smoking and greasy spillovers that may ignite. Heat oils slowly on low or

 

medium settings.

2.

Always turn hood ON when cooking at high heat or when cooking

 

flaming foods.

For Use With Hood Models:

VCWH4848 DCWH4844

VCWH5448 DCIH5404

VCWH6048 DCWL5144

VCWH6648 DCWN4844

VCIH5408VCIH6608

Blower Dimensions

22.528 x 12.031 x 10.639

VENTILATOR KIT

INSTALLATION

1.Remove REAR FILTER RAIL from hood.

2.Lift VENTILATOR into position inside the hood.

3.Engage two (2) TABS on ventilator into two (2) SLOTS in TOP OF HOOD. Secure ventilator to THREADED STUDS with two (2) HEX NUTS (provided).

4.Plug ventilator's POWER CORDS into RECEPTACLES inside the hood.

3.

Clean ventilating fans frequently. Grease should not be allowed to

 

accumulate on fan or filter.

4.

Use proper pan size. Always use cookware appropriate for the size of

 

the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION Manual background!

1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impel- lers, keep drywall spray, construction dust, etc. off power unit.

3.Your ventilator motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.

4.Please read specification label on product for further information and requirements.

5. Replace rear filter rail.

TOP OF

HOOD

SLOT

TAB

VENTILATOR

REAR FILTER RAIL

THREADED

STUDS

RECEPTACLES

POWER

CORDS

F20076

HEX NUTS

99043022C

Page 1
Image 1
Viking dimensions Model DIV1200 Ventilator Kit, Ventilator Kit Installation, Blower Dimensions